Normal Open Circuit Weld Voltage Waveform (High Cv Mode - Lincoln Electric RANGER SVM148-B Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-47

NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM (HIGH CV MODE)

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM
TROUBLESHOOTING & REPAIR
20 volts
This is the typical CV output voltage
generated from a properly operating
machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents 5
milliseconds in time.
Note: Scope probes connected at
machine output terminals.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal
RANGER 300 D AND 300 DLX
0 volts
5 ms
F-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ranger 300 dRanger 300 dlx

Table of Contents