Normal Open Circuit Ac Weld Voltage Waveform - Lincoln Electric RANGER SVM148-B Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-49

NORMAL OPEN CIRCUIT AC WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM
TROUBLESHOOTING & REPAIR
50 volts
This is the typical AC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 50 volts and that
each horizontal division represents 5
milliseconds in time.
Note: Scope probes connected at
machine output terminals.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal
RANGER 300 D AND 300 DLX
0 volts
5 ms
F-49