Control Cable; Control Cable Connection; Control Cable Specifications; Available Control Cable - Lincoln Electric POWERFEED IM827-D Operator's Manual

Single wire feeder
Table of Contents

Advertisement

A-5
DIP Switch #7 Position
ON
OFF
FIGURE A.3

CONTROL CAbLE

CONTROL CAbLE CONNECTIONS
• All system control cables are the same.
• All control cables can be connected end to end to
extend their length.
• All system equipment must be connected to a con-
trol cable.
Typical bench Feeder Connection:
Control cable is connected from the Power Wave
Source output Amphenol receptacle to the input
Amphenol receptacle on the back of the Wire Drive.
Digital Control Cable, K1543-xx
Power Source
Amphenol Plug
E
D
A
C
B
Wi r e Feeder
Amphenol
AB
CD
E
Tri g ger Lead
Wel d i n g Gun
Pin
Function
A
Digital I/O
B
Digital I/O
C
"67" voltage sense
D
40 VDC
E
40 VDC
Use a maximum of 250 feet (76.2m) of control cable
between components.
INSTALLATION
Polarity
(negative) - polarity
(positive) + polarity
Wire Feeder
Amphenol Plug
E
D
A
B
C
POWER FEED™ 10M SINGLE WIRE FEEDER
Welding Gun/Wire Feeder Trigger Connector
Wire Feeder
Amphenol
E
D
A
Trigger Lead
B
C
Wire Feeder
Pin
Function
A
Gun Trigger
B
-
C
Common
D
Dual Procedure
E
Common

CONTROL CAbLE SPECIFICATIONS

It is recommended that only genuine Lincoln control
cables be used at all times. Lincoln cables are specifi-
cally designed for the communication and power
needs of the Power Wave Source / Power Feed sys-
tem. The use of non-standard cables, especially in
lengths greater than 25ft(7.6m), can lead to communi-
cation problems (system shutdowns), poor motor
acceleration (poor arc starting) and low wire driving
force (wire feeding problems).
Lincoln control cables are copper 5 conductor cable in
a SO-type rubber jacket. There is one 20 gauge twist-
ed pair for network communications. This pair has an
impedance of approximately 120 ohms and a propa-
gation delay per foot of less than 2.1 nanoseconds.
There are two 12 gauge conductors that are used to
supply the 40 VDC to the network. The fifth wire is 18
gauge and is used as an electrode sense lead.

AVAILAbLE CONTROL CAbLE

K1543 Control cable only. Available in lengths of
8'(2.4m), 16'(4.9m), 25'(7.6m), 50'(15.2m) and
100'(30.5m).
A-5
Welding Gun

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power feed 10m

Table of Contents