Troubleshooting External Connections; Installation Problems - QUANTA STRATOS S210 Series S210-X12MS Technical Manual

Two socket high performance &
Table of Contents

Advertisement

T
ROUBLESHOOTING
1. Power down the server. Do not unplug the power cord.
2. Open the server chassis
3. Move the CMOS CLEAR jumper from the default opera-
tion position, covering pins 1 and 2, to the reset / clear
CMOS, covering pins 2 and 3.
4. Remove AC power.
5. Wait 5 seconds.
6. Move the jumper back to default position, covering pins 1
and 2.
7. Close the server chassis and power up the server.
The CMOS is now cleared and can be reset by going into BIOS
setup.
Please refer to www.qsscit.com for the BIOS update.

Installation Problems

Perform the following checks if you are troubleshooting an
installation problem:
Check all cable and power connections (including all rack cable
connections). Unplug the power cord, and wait one minute.
Then reconnect the power cord and try again. If the network is
reporting an error, see if the server has enough memory and
disk space available. Remove all added options, one at a time,
and try to power up the system. If after removing an option the
server works, you may find that it is a problem with the option or
a configuration problem between the option and the server.
Contact the option vendor for assistance.
If the system doesn't power on, check the LED display. If
the power LED is not on, you may not be receiving AC
power. Check the AC power cord to make sure that it is
securely connected.

Troubleshooting External Connections

Loose or improperly connected cables are the most likely
source of problems for the system, monitor, and other
peripherals (such as a keyboard, mouse, or other external
device). Ensure that all external cables are securely attached to
the external connectors on your system.