A-7
ELECTRICAL OUTPUT
CONNECTIONS
See Figure A.2 for the location of the 115V DC volt
receptacle, weld output terminals, and ground stud.

WELDING CABLE CONNECTIONS

CABLE INSTALLATION AND CABLE SIZES

With the engine off, route the electrode and work
cables through the strain relief bracket on the base and
connect to the terminals located below the fuel tank
mounting rail. (See size recommendations below.) For
positive polarity, connect the electrode cable to the ter-
minal marked Positive (+). For Negative polarity, con-
nect the electrode cable to the Negative (-) terminal.
These connections should be checked periodically and
tightened if necessary.
2
4
TABLE A.1 - RECOMMENDED COPPER WELDING CABLE SIZE AND LENGTH
TOTAL COMBINED LENGTH OF ELECTRODE AND WORK CABLES
Amps
200
INSTALLATION
FIGURE A.2 - CLASSIC I OUTPUT CONNECTIONS
Duty Cycle
60%
CLASSIC I
CAUTION
• Loose connections will cause the output terminals to
overheat. The terminals may eventually melt.
• Do not cross the welding cables at the output termi-
nal connection. Keep the cables isolated and sepa-
rate from one another.
When welding at a considerable distance from the
welder, be sure you use ample size welding cables.
Table A.1 lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
Lincoln Electric offers a welding accessory kit with the
properly specified welding cables. See the Accessories
section of this manual for more information.
AUXILIARY POWER RECEPTACLE,
PLUGS, AND HAND-HELD EQUIPMENT
The DC auxiliary power, supplied as a standard, has a
rating of 1.75 kw of 120V DC.
1
3
1. 120 VOLT DC RECEPTACLE
2. WELD OUTPUT TERMINALS (2)
3. GROUND STUD (LOCATION)
4. CABLE STRAIN RELIEF BRACKET
Cable size for combined length of
electrode plus work cable
Up to 200 ft.
1
A-7
200 to 250 ft.
1/0