Heat & Glo ESCAPE-I35-F Owner's Manual page 12

Hide thumbs Also See for ESCAPE-I35-F:
Table of Contents

Advertisement

5. Module Reset
This module may lock-out under certain conditions.
when this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying a REd/gREEN error code at its status
indicator lEd.
• Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section g.
• locate the module reset switch. (See Figure 3.7).
• Set the module reset switch to the OFF position.
• wait five (5) minutes to allow possible accumulated gas
to clear.
• Set the module reset switch to ON or REMOTE position.
• Start the appliance.
WArNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a five minute
time period. Gas may accumulate in firebox. Call a quali-
fied service technician.
Nine Hour Safety Shutdown Feature
The appliance has a safety feature that automatically
shuts down the fireplace after nine hours of continuous
operation without receiving a command from the wall
switch or optional remote.
MODULE RESET SWITCH
Figure 3.7. Module Reset Switch
12
Heat & Glo • Escape-I35-F, Escape-I30-F Owner's Manual • 2347-981 Rev. F • 8/14
Appliance ON/OFF:
The appliance may be turned on and off by the RC300 re-
mote control that comes standard with the fireplace. Con-
sult the instructions and quick reference guide included
with the RC300 for more information.
Fan ON/OFF:
The fan may be turned on and off and the speed adjusted
by the RC300 remote control that comes standard with
the fireplace. Consult the instructions and quick refer-
ence guide included with the RC300 for more information.