5.
CAPACITY TABLE
5-1.
COMBINATIONS
MODEL
: AOG14L2
z
Cooling
Combination
of Indoor Unit
Room 1 Room 2
kW
kW
7
7
2.00
2.00
7
9
1.95
2.05
2 Room
7
12
1.65
2.35
9
9
2.00
2.00
9
12
1.70
2.30
z
Heating
Combination
of Indoor Unit
Room 1 Room 2
kW
kW
7
7
2.20
2.20
7
9
2.15
2.25
2 Room
7
12
1.95
2.45
9
9
2.20
2.20
9
12
2.00
2.40
Notes:
•
7: 7000Btu/h, 9: 9000Btu/h, 12: 12000Btu/h models.
•
The above is the value for connecting with Wall Mounted type.
•
2 or more indoor units should be connected.
•
Cooling capacity is based on 27 °CDB / 19 °CWB (indoor temperature), 35 °CDB (outdoor temperature).
•
Heating capacity is based on 20 °CDB (indoor temperature), 7 °CDB / 6 °CWB (outdoor temperature).
•
Pipe length :5m, Height difference :0m. (Outdoor unit to indoor unit)
•
The total ability of connected a indoor unit is up to 21000 Btu from 14000 Btu.
COOLING OPERATION
Cooling Capacity
Input Power
Total Capacity
(min-max)
(min-max)
kW
4.00 ( 1.4 - 4.4 )
1.09 ( 0.35 - 1.40 )
4.00 ( 1.4 - 4.4 )
1.09 ( 0.35 - 1.40 )
4.00 ( 1.4 - 4.6 )
1.05 ( 0.35 - 1.47 )
4.00 ( 1.4 - 4.5 )
1.09 ( 0.35 - 1.43 )
4.00 ( 1.4 - 4.7 )
1.05 ( 0.35 - 1.47 )
HEATING OPERATION
Heating Capacity
Input Power
Total Capacity
(min-max)
(min-max)
kW
4.40 ( 1.1 - 5.4 )
1.03 ( 0.25 - 1.78 )
4.40 ( 1.1 - 5.4 )
1.03 ( 0.25 - 1.78 )
4.40 ( 1.1 - 5.5 )
1.02 ( 0.25 - 1.76 )
4.40 ( 1.1 - 5.4 )
1.03 ( 0.25 - 1.78 )
4.40 ( 1.1 - 5.5 )
1.02 ( 0.25 - 1.76 )
Seasonal Data
EER
Pdesign
kW
kW
3.67
4.0
3.67
4.0
3.81
4.0
3.67
4.0
3.81
4.0
Seasonal Data
COP
Pdesign
kW
kW
4.27
3.8
4.27
3.8
4.31
3.8
4.27
3.8
4.31
3.8
- (02 - 09) -
Energy
Efficiency
SEER
Class
6.7
A++
6.6
A++
6.5
A++
6.6
A++
6.5
A++
Energy
Efficiency
SCOP
Class
4.1
A+
4.1
A+
4.0
A+
4.0
A+
4.0
A+