FEATURES MODELS ARG12LLTB / AOG12LALL ARG12LLTB ARG18LLTB ARG14LLTB / AOG14LALL ARG14LLTB ARG18LLTB / AOG18LALL FEATURES Energy efficiency class MODEL AR G12LLTB AR G14LLTB AR G18LLTB Cooling Heating Slim design Air - intake ...
WIRED REMOTE CONTROLLER FEATURES Various timer setup available (ON / OFF / WEEKLY). Equipped with weekly timer as standard function. (2 sets of start/stop per day for a week.) When setting up the timer, operation mode and temperature setup ...
FUNCTIONS START/STOP button Pressed to start and stop operation. SET TEMP. button Selects the setting temperature. MODE button Selects the operating mode (AUTO, HEAT, FAN, COOL, DRY). FAN button Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH). ECONOMY (THERMO SENSOR) button Turns the economy efficient mode on and off.
SPECIFICATIONS DUCTED MODEL Type INVERTER HEATPUMP Model name ARG12LLTB ARG14LLTB ARG18LLTB Power source 230V ~ 50Hz Available voltage range 198 - 264V ~ 50Hz 3.50 4.30 5.20 Rated Btu/h 11950 14650 17700 Cooling 0.90 - 4.40 0.90 - 5.40 0.90 - 5.90 Min - Max Btu/h 3100 - 15000...
Page 8
Model name ARG12LLTB ARG14LLTB ARG18LLTB Cooling Energy efficiency class Heating (Average) Cooling 3.5(35°C) 4.3(35°C) 5.2(35°C) Pdesign Heating (Average) 4.2(-10°C) 4.5(-10°C) 5.2(-10°C) SEER Cooling 5.90 5.80 6.20 kWh/kWh SCOP Heating (Average) 4.00 3.90 4.10 Annual energy consumption kWh/a QHE (Average) 1467 1614 1774 Cooling...
DIMENSIONS MODELS: AR G12LLTB, ARG14LLTB (Unit : mm) View A Rear view (Drain hose) Drain port 100 x 6 = 600 Side view Top view Front view Bottom view AR G12LL AR G14LL Liquid ø 6.35 mm (ø 1/4 in.) ...
Page 10
Unit : mm MODEL : AR G18LLTB Rear view View A (Drain hose) Drain port 100 x 8 = 800 Top view Side view Front view Bottom view AR G18LL Liquid ø 6.35 mm (ø 1/4 in.) ...
Unit : mm INSTALLATION PLACE 300 or more Strong and durable ceiling 20 or more Indoor unit Left Right side side 20 or more Service access Ceiling or more or more Floor or less or less Left side Right side (PIPE side) Grill...
Page 12
MAINTENANCE SPACE Unit : mm Provide a service access for inspection purposes as shown below. Do not place any wiring or illumination in the service space, as they will impede service. Service access Unit Control or more Service space - (01 - 09) -...
WIRING DIAGRAMS MODELS : AR G12LLTB, AR G14LLTB, AR G18LLTB THERMISTOR GRAY (PIPE TEMP.) GRAY BLACK THERMISTOR BLACK (ROOM TEMP.) LOUVER PRINTED RECEIVER UNIT (OPTION) CIRCUIT (OPTION) BOARD FLOAT SWITCH (MAIN) BLACK BLACK WHITE BLACK TERMINAL HEATER FRESH AIR...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTIONS Conditions MODEL : AR G12LLTB (UTD-GXSA-W) Fan speed : High Operation mode : Fan Note: This data is measured with the Auto louver grille kit(option) installed. Air velocity distribution Unit: m/s Top view Vertical flap : Up Horizontal flap : Center...
Page 17
Conditions Fan speed : High Note: This data is measured with the Auto louver grille kit(option) installed. Operation mode : Heat Air velocity distribution Reference Data Unit: m/s Side view Vertical flap : Down Horizontal flap : Center Air temperature distribution ...
Page 18
Conditions MODEL : AR G14LLTB (UTD-GXSA-W) Fan speed : High Operation mode : Fan Note: This data is measured with the Auto louver grille kit(option) installed. Air velocity distribution Unit: m/s Top view Vertical flap : Up Horizontal flap : Center Unit: m/s Top view...
Page 19
Conditions Fan speed : High Note: This data is measured with the Auto louver grille kit(option) installed. Operation mode : Heat Air velocity distribution Reference Data Unit: m/s Side view Vertical flap : Down Horizontal flap : Center Air temperature distribution ...
Page 20
Conditions MODEL : AR G18LLTB (UTD-GXSB-W) Fan speed : High Operation mode : Fan Note: This data is measured with the Auto louver grille kit(option) installed. Air velocity distribution Unit: m/s Top view Vertical flap : Up Horizontal flap : Center Unit: m/s Top view...
Page 21
Conditions Fan speed : High Note: This data is measured with the Auto louver grille kit(option) installed. Operation mode : Heat Air velocity distribution Reference Data Unit: m/s Side view Vertical flap : Down Horizontal flap : Center Air temperature distribution ...
7-3. AIRFLOW MODEL : AR G12LLTB Cooling Number of Fan speed rotations Airflow (r.p.m.) HIGH 1340 1240 1140 QUIET 1030 Heating Number of Fan speed rotations Airflow (r.p.m.) HIGH 1340 1240 1140 QUIET 1030 - (01 - 25) -...
Page 29
MODEL : AR G14LLTB Cooling Number of Fan speed rotations Airflow (r.p.m.) HIGH 1560 1400 1240 QUIET 1030 Heating Number of Fan speed rotations Airflow (r.p.m.) HIGH 1560 1400 1240 QUIET 1030 - (01 - 26) -...
Page 30
MODEL : AR G18LLTB Cooling Number of Fan speed rotations Airflow (r.p.m.) HIGH 1380 1300 1220 QUIET 1140 Heating Number of Fan speed rotations Airflow (r.p.m.) HIGH 1380 1300 1220 QUIET 1140 - (01 - 27) -...
ELECTRIC CHARACTERISTICS Model name ARG12LLTB ARG14LLTB ARG18LLTB Voltage 230 ~ Power supply Frequency Max. operating current 0.44 0.64 0.55 Connection cable *1) Wiring Spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005) - (01 - 31) -...
SAFETY DEVICES Model Protection form ARG12LLTB ARG14LLTB ARG18LLTB Circuit protection Current fuse (PCB) 250V 3.15A Over current protection 1.90 ± 0.24A Fan motor protection 138 ± 15°C OFF Thermal protection program 115 ± 15°C ON - (01 - 32) -...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor unit Connected unit control PC board Connector Ex.)Relay unit Ex.)Display 24V DC Relay power supply *10 m Signal Field supply * Make the distance from the PC board to the connected unit within 10m.
Page 38
FRESH AIR CONTROL OUTPUT A signal linked to air conditioner indoor fan ON can be output. * However, signal becomes OFF during cold air prevention control operation. Circuit diagram example Indoor unit Connected unit control PC board Ex.) Fan Ex.) Relay unit 12 V...
Page 39
AUXILIARY HEATER OUTPUT A signal is outputed from Connector when indoor fan and compressor is turned on under heating operation. Tr-Ts * Signal output performance specifications are as Tr-Ts = -1°C shown on the right Tr-Ts = -3°C Ex.
FUNCTION SETTINGS 12-1. INDOOR UNIT INDOOR UNIT DIP SW Remote controller address setting Drainage function setting Jumper Wire Auto louver grille setting Fan delay setting SWITCH POSITION DIP-SW SETTING Remote controller address setting A number of indoor units can be operated at the same time using a wired remote controller. Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board.
Page 41
JUMPER WIRE SETTING Drainage function setting (JM1) (u...Factory setting) Drainage function Connect Valid Disconnect Invalid Auto louver grille setting (JM2) When Auto louver grille kit (optional parts) is attached, set the Auto louver grille setting to "Valid". (u...Factory setting) Auto louver grille setting Connect...
12-2. INDOOR UNIT (Setting by remote controller) ● The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. ● After the power is turned on, perform the Function Setting according to the installation conditions using the remote controller.
Page 43
(5) Press the TIMER SET button to confirm the setting. Press the TIMER SET button for a few seconds until the setting value stops flashing. If the setting value display changes or if “- -” is displayed when the flashing stops, the setting value has not been set correctly. (An invalid setting value may have been selected for the indoor unit.) (6) Repeat steps 2 to 5 to perform additional settings.
Page 44
CONTENTS OF FUNCTION SETTING • Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in accordance with the installed condition. After the power is turned on, perform the Function Setting on the remote control. •...
Page 45
4) Heater room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as shown in the table below. ( ... Factory setting) Setting description Function number Setting value Standard ...
Page 46
9) Indoor unit fan control for energy saving (Only cooling mode) Enable or disable indoor unit fan control when the outdoor unit is stopped. ( ... Factory setting) Setting description Function number Setting value * If setting value is "00": When the outdoor unit is stopped, the indoor unit fan operates following the setting on the remote controller continuously.
OPTIONAL PARTS 13-1. CONTROLLER Exterior Parts name Model No. Summary Large and full-dot liquid Wired remote crystal screen, wide and UTY-RVN M controller large keys easy to press, user-intuitive arrow key. The room temperature can Wired remote be controlled by detecting UTY-RNN ...
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AO G12LALL AO G14LALL AO G18LALL AO G24LALA Power source 230V ~ 50Hz Available voltage range 198 - 264V ~ 50Hz Starting current Cooling 1780 1910 2000 2470 Airflow rate Heating 1630 1740...
DIMENSIONS MODEL : AOG12LALL, AOG14LALL, AOG18LALL, AOG24LALA (Unit : mm) Top view Front view AO G12LALL AO G24LALA AO G14LALL AO G18LALL Air flow Side view Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE This table is created using the maximum capacity. MODEL : AOG12LALL Pipe length (m) COOLING 0.903 0.894 0.867 Û 1 0.964 0.918 0.909 0.881 Indoor unit is higher than 0.988 0.968 0.922...
Page 57
This table is created using the maximum capacity. MODEL : AOG14LALL Pipe length (m) COOLING 0.953 0.950 0.947 Û 1 0.983 0.968 0.966 0.962 Indoor unit is higher than 0.988 0.987 0.972 0.970 0.966 outdoor unit. 0.992 0.992 0.991 0.976 0.974...
Page 58
This table is created using the maximum capacity. MODEL : AOG18LALL Pipe length (m) COOLING 0.953 0.950 0.947 Û 1 0.983 0.968 0.966 0.962 Indoor unit is higher than 0.988 0.987 0.972 0.970 0.966 outdoor unit. 0.992 0.992 0.991 0.976 0.974...
Page 59
This table is created using the maximum capacity. MODEL : AOG24LALA Pipe length (m) COOLING 0.963 0.961 0.959 Û 1 0.984 0.981 0.979 0.977 0.975 Indoor unit is higher than 0.988 0.988 0.985 0.983 0.981 0.979 outdoor unit. 0.992 0.992 0.992...
AIRFLOW MODEL : AOG12LALL Cooling Number of rotations Airflow (r.p.m.) 1780 1048 Heating Number of rotations Airflow (r.p.m.) 1630 MODEL : AOG14LALL Cooling Number of rotations Airflow (r.p.m.) 1910 1124 Heating Number of rotations Airflow (r.p.m.)
Page 62
MODEL : AOG18LALL Cooling Number of rotations Airflow (r.p.m.) 2000 1177 Heating Number of rotations Airflow (r.p.m.) 1910 1124 MODEL : AOG24LALA Cooling Number of rotations Airflow (r.p.m.) 2470 1050 1454 Heating Number of rotations Airflow...
ELECTRIC CHARACTERISTICS Model name AOG12LALL AOG14LALL AOG18LALL AOG24LALA Voltage 230 ~ Power supply Frequency *1) Max operating current 10.0 12.5 13.5 Starting Current Main Fuse (Circuit breaker) *2) Wiring Spec. Current Power Cable *1) The maximum current is the total current of indoor unit and outdoor unit. *2) Wiring Spec.: Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005)
SAFETY DEVICES Model Protection form AO G12LALL AO G14LALL AO G18LALL AO G24LALA 250V 20A Current fuse (Near the terminal) 250V 5A Circuit protection Current fuse 250V 15A (Main printed 250V 3.15A circuit board) Fan motor Thermal protection OFF : 100 °C...