8) Auto restart
Enable or disable automatic restart after a power interruption.
Function number
Setting value
40
* Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external device.
9) Room temperature sensor switching
(Only for Wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
Function number
Setting value
42
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller is active.
*Remote controller sensor must be turned on by using the remote controller.
10) Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed.
Select the appropriate custom code.
Function number
Setting value
44
11) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
Function number
Setting value
46
12) Room temperature sensor switching (Aux)
To use the temperature sensor on the wired remote controller only, change the setting to
"Wired remote controller" (01). This function will only work if the function setting 42 is set at
"Both" (01)
Function number
Setting value
48
(  ... Factory setting)
Setting description
Enable
00
Disable
01
(  ... Factory setting)
Setting description
Indoor unit
00
Both
01
(  ... Factory setting)
Setting description
00
01
02
03
(  ... Factory setting)
Setting description
Operation/Stop mode
00
(Setting prohibited)
01
Forced stop mode
02
(  ... Factory setting)
Setting description
Both
00
Wired remote controller
01
- (01-177) -
A
B
C
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents