parallel Installation:
Minimum clearance and Flue centerline,
Direct Vent and Natural Vent
C
D
C L
B
Stove Clearances
Pipe Centerlines
ST128b
Fig. 3 Parallel installation, minimum back and side clearances
Stardance
and flue centerlines.
flue centerline
corner Installation:
9/28/00 djt
Minimum clearance and Flue centerline
Direct Vent and Natural Vent
B
B
A
Stove Clearance
Pipe Centerline
Fig. 4 Corner installation, minimum corner clearances and flue
centerline.
30005123
C L
A
A: 4" (102 mm)
B: 4" (102 mm)
C: 15Z\x" (395 mm)
D: 9" (229 mm)
A
A: 4" (102 mm)
B: 14Z\x" (370 mm)
ST129c
Dutchwest
corner specs
5/15/03 djt
Oxford Direct Vent / Natural Vent Gas Heater
Wall centerline from Floor
Effective Minimum
ST128c
Wall Thimble
Pipe)
Centerline
Fig. 5 Minimum wall thimble centerline.

Wall and ceiling clearances

A: Rear Wall
B: Min. Clearance
C: Min. Alcove Height
D: Max. Alcove Depth
Sidewall Clearance
* needed for installing DuraVent Minimum Vent Kit #2792 or Vermont Cast-
ings Group Minimum Vent Kit #7TFSDVSK.
ST129c
Fig. 6 Dimensions and clearances to ceiling or alcove.
The heater must be installed on rigid flooring. When the
heater is installed directly on any combustible surface
other than wood flooring, a metal or wood panel extend-
ing the full width and depth of the unit must be used as the
hearth. There are no other hearth requirements.
A
A
57Z\x" (1461 mm) (Vermont Castings Group
ST1121
53Z\x" (1359 mm) (Simpson DuraVent Pipe)
wall thimble
D
B
C
A
4" (102 mm)
45Z\x" (1156 mm)*
ST1122
73Z\x" (1867 mm)*
Min. clearance
48" (1220 mm)
4" (102 mm)

Hearth Requirements

ST1121
ST1122
7