E
F
Fig. 51 Replace regulator.
FC108
pilot Orifice conversion
SIT
1. Locate pilot. (Fig. 49)
regulator
2. Replace pilot orifice.
conversion
pilot Type 1
10/03
• Remove pilot hood by lifting up. (Fig. 52) Do not re-
move snap ring to remove pilot hood. NOTE: It is not
necessary to remove the pilot tube for conversion.
• Remove pilot orifice with allen wrench. (Fig. 53)
• Install the conversion orifice.
• Reinstall pilot hood. Be sure to align hood with index
tab.
Pilot Hood
Pilot
Bracket
Fig. 52 Remove pilot hood.
Index Tab
Snap Ring
Fig. 53 Remove pilot orifice.
CO106a
DV360/580
Gas Conversion
Pilot2
28
1/28/00 djt
D
FC108
CO105a
Allen Wrench
CO105a
gas conversion
Pilot
1/28/00 djt
CO106a
pilot type 2
• Loosen pilot hood turning counterclockwise using a
7/16" wrench. (Fig. 54) NOTE: You may use pene-
trating oil to prevent pilot hood threads from seizing
up.
• Remove pilot orifice with needlenose pliers. (Fig.
55) NOTE: Use a wrench to hold pilot tube in place
while removing the orifice.
• Install the conversion orifice.
• Reinstall pilot hood and tighten until mark on pilot
hood aligns with mark on pilot bracket.
NOTE: Be sure burner leg remains at a 90° angle to fire-
box base after conversion.
Index
Marks
Pilot Bracket
Fig. 54 Remove pilot hood. (Your pilot may have a different
appearance).
Fig. 55 Remove pilot orifice.
21. Replace burner. Slide the burner in at an angle with
left side lower than the right side. Slide the left side
CO106a
onto the injectors, making sure the burner leg remains
Gas Conversion
at a 90° angle to the base. Lower the right hand side
Pilot (Vermont)
down in to place. Make sure the burner is as far left
as possible and the injector shoulders are inside the
7/19/99 djt
burner.
NOTE: It is very critical to keep the left burner leg, which
holds the injectors, at a 90° angle to the base. (Fig. 56)
This keeps the orifices aligned with the tubes inside
burner. Failure to do so could affect the flame appear-
ance and performance of the unit.
22.Place conversion label on valve.
Pilot
CO105
CO105
Gas Conversion
Pilot Orifice
Pilot
2/15/99 djt
CO106b
30005123