ODSR Series "A" Outdoor Woodburning Fireplace For Models: ODSR36A ODSR42A Homeowner's Installation and Operating Manual SR cover 11/18/97 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future refer- ence. 20006811 1/13 Rev. 15...
Group dealer. the structure's weather envelope. Where the platform Only use Vermont Castings Group components or the war- meets the wall, use a flashing detail similar to that required ranty will be voided and a fire hazard may be created.
1/4" per foot away from any structure. Blocking FP1531 Front Width Back Width Depth 1/2” (13 mm) FP1531 ODSR36A 31¹⁄₈" 19⁷⁄₈" 15¹⁄₂" hearth dimensions (791 mm) (505 mm) (394 mm) 9/04 djt Metal Safety Strips ODSC42A 36³⁄₄"...
Page 6
ODSR Series "A" Outdoor Woodburning Fireplace NOTE: If the fireplace is a freestanding unit, it must be located a minimum of 10' (3 m) from the opening of the firebox to a combustible structure. A minimum height of 6'4" (1.9 m) measured from the base of the firebox to the 6'4"...
FP288 3. A chimney may run straight up or it may be necessary MBUF-INSTALLED LENGTH When installed on exterior walls: Vermont Castings to offset it to avoid obstructions. 6/17/96 Group recommends the fireplace chase be constructed 4. The maximum length of an angled run (total chimney outside the structure's weather envelope.
ODSR Series "A" Outdoor Woodburning Fireplace Installation 0 To 10' Insulating Fireplace Enclosure 2' Min. 0 To 10' for Cold Climates Min. 2' Min. If you live in a cold climate, it is not required but highly Min. recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.
This is accomplished by us- Possible Obstructions ing Vermont Castings Group elbows. Use the 30° Offset The size of the hole in ceiling will vary with the angle at Elbow table on Page 5 to determine proper offset and which the chimney passes through ceiling.
ODSR Series "A" Outdoor Woodburning Fireplace Cutting the hole Cover fireplace collar opening and cut proper sized chim- ney hole in chimney. The SK8 pipe allows you to run pipe through a typical 16” on center joist without cutting joists. Metal Safety Strips (1, 2 or 3 pieces) Framing the Ceiling hole...
ODSR Series "A" Outdoor Woodburning Fireplace Installing Outside Air Kit Elbow Strap Support Structure An outside air kit is not installed in all ODSR Series "A" Fireplaces. If desired, or if local codes mandate the use of an air kit, then an AKU1 is required . If the outside air kit is to be used, the AKU1 MUST be installed BEFORE the fireplace is enclosed.
Page 13
(4 required) Size of roof hole varies with the type of chimney termina- tion installed. Refer to installation instructions provided with Vermont Castings Group chimney termination to find correct size of roof hole. Attic Joist There must be a 1¹⁄₂ (38 mm) air space between outermost portion of chimney sections and any adjacent combustible surfaces.
Space requirements for your city or state. NOTE: Other building to Sides materials may be required in addition to Vermont Castings Group Firestop Spacers. Finishing CAUTION: All joints between the finished wall and the 0"...
Page 15
ODSR Series "A" Outdoor Woodburning Fireplace Mantel Clearance - Mantel Clearance - with Noncombustible Facing Material No Noncombustible Facing Material Combustible Mantel 12" 12" Combustible Mantel and Trim (305mm) and Trim (305mm) Finished Wall Finished Wall Max. Max. 1¹⁄₂" 1¹⁄₂" Header Header (38mm)
Figure 24 of fireplace opening dimensions and mounting detail. must be protected with Vermont Castings Group Wall Shield Model SP40 or a specifically built wall shield described NOTE: hearth Extension must not cover the air inlet below.
Page 17
ODSR Series "A" Outdoor Woodburning Fireplace Side View COMMON MATERIALS AND FACTORS Wall Covering MINIMUM MATERIAL THICKNESS Noncombus- 2 x 4 Header EH2416 tible Decorative (Do not notch 0.458 1.09 0.50 in.** Facing (MHSC) at standoffs) Seal all cracks between fireplace sur- Common Brick 0.10 5.46 in.**...
Vermont Castings Group fireplaces are designed to ac- cept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (Vermont Castings Group manufactures a 1" wide variety of gas logs for use in Vermont Castings Group Min. Supply Line Gas Line Fireplaces.)
ODSR Series "A" Outdoor Woodburning Fireplace 6811 Vermont Castings Group reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODSR36A/42A Outdoor Woodburning Fireplace Item/Model Number ODSR36A ODSR42A 1. Damper Weld Assembly...
ODSR Series "A" Outdoor Woodburning Fireplace Accessories The following accessories for this appliance are available from your local Vermont Castings Group distributor. Should you need additional information beyond what your distributor can furnish, contact: Vermont Castings Group, 149 Cleveland Drive, Paris, KY 40361, Attn: Technical Services.
ODSR Series "A" Outdoor Woodburning Fireplace Chimney Components U.S. Component Description Model Number Round Top Termination Top used to terminate chimney at roof. RLTSK8 (Flashing not included.) Round Top Termination - Top used to terminate chimney at chase. RLTSK8L Extended (Flashing not included.) Flashing Metal finishing required around Contemporary...
Page 22
ODSR Series "A" Outdoor Woodburning Fireplace (Chimney Components con't.) Canada Component Description Model Number Chimney Collar Enclosure Installs on the "over the chimney collar" of the CCE-SK fireplace; provides outside air to assist in cooling the chimney system. Attic Insulation Shield Used to prevent insulation from coming in AIS-SK contact with the chimney system.
Limitations and Exclusions 1. No one has authority to add to or vary this limited warranty, or to create for Vermont Castings Group any other obligations of liability in connection with this fireplace and accessory.