Vermont Castings ODSR36A Installation And Operating Manual

Odsr series "a" outdoor woodburning fireplace

Advertisement

Quick Links

ODSR Series "A"
Outdoor Woodburning Fireplace
948
SR cover
11/18/97
For Models:
ODSR36A
ODSR42A
Homeowner's Installation
and Operating Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future refer-
ence.
20006811 1/13 Rev. 15

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings ODSR36A

  • Page 1 ODSR Series "A" Outdoor Woodburning Fireplace For Models: ODSR36A ODSR42A Homeowner's Installation and Operating Manual SR cover 11/18/97 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future refer- ence. 20006811 1/13 Rev. 15...
  • Page 2: Table Of Contents

    Warranty ............23 Proposition 65 Warning: Fuels used in gas, wood- ODSR36A / ODSR42A burning or oil fired appliances, and the products of...
  • Page 3: Safety Information

    Group dealer. the structure's weather envelope. Where the platform Only use Vermont Castings Group components or the war- meets the wall, use a flashing detail similar to that required ranty will be voided and a fire hazard may be created.
  • Page 4: Specifications And Framing

    14 " (372 mm) 11" 7 " (279 mm) (197 mm) 8" 40" (203 mm) (1016 mm) Fig. 1 ODSR36A specifications and framing. ODSR42A Woodburning Fireplace — Circulating Model 6811 ODSR36 Minimum 26 " specs Rough (667 mm) Opening 9/03 Depth 50"...
  • Page 5: Hearth Dimensions

    1/4" per foot away from any structure. Blocking FP1531 Front Width Back Width Depth 1/2” (13 mm) FP1531 ODSR36A 31¹⁄₈" 19⁷⁄₈" 15¹⁄₂" hearth dimensions (791 mm) (505 mm) (394 mm) 9/04 djt Metal Safety Strips ODSC42A 36³⁄₄"...
  • Page 6 ODSR Series "A" Outdoor Woodburning Fireplace NOTE: If the fireplace is a freestanding unit, it must be located a minimum of 10' (3 m) from the opening of the firebox to a combustible structure. A minimum height of 6'4" (1.9 m) measured from the base of the firebox to the 6'4"...
  • Page 7: Chimney Requirements

    20 feet. (G 0 1 1 2 2 78" 140³⁄₄" plus H cannot exceed 20 feet.) 0 0 3 1 2 81" 146" ODSR36A ODSR42A E. A chimney support (Model SKCS8) 0 1 0 3 2 84" 151¹⁄₄" Maximum: 90'0"...
  • Page 8: Planning Information

    FP288 3. A chimney may run straight up or it may be necessary MBUF-INSTALLED LENGTH When installed on exterior walls: Vermont Castings to offset it to avoid obstructions. 6/17/96 Group recommends the fireplace chase be constructed 4. The maximum length of an angled run (total chimney outside the structure's weather envelope.
  • Page 9: Chimney Supports

    ODSR Series "A" Outdoor Woodburning Fireplace Installation 0 To 10' Insulating Fireplace Enclosure 2' Min. 0 To 10' for Cold Climates Min. 2' Min. If you live in a cold climate, it is not required but highly Min. recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.
  • Page 10: Framing

    This is accomplished by us- Possible Obstructions ing Vermont Castings Group elbows. Use the 30° Offset The size of the hole in ceiling will vary with the angle at Elbow table on Page 5 to determine proper offset and which the chimney passes through ceiling.
  • Page 11: Cutting The Hole

    ODSR Series "A" Outdoor Woodburning Fireplace Cutting the hole Cover fireplace collar opening and cut proper sized chim- ney hole in chimney. The SK8 pipe allows you to run pipe through a typical 16” on center joist without cutting joists. Metal Safety Strips (1, 2 or 3 pieces) Framing the Ceiling hole...
  • Page 12: Installing Outside Air Kit

    ODSR Series "A" Outdoor Woodburning Fireplace Installing Outside Air Kit Elbow Strap Support Structure An outside air kit is not installed in all ODSR Series "A" Fireplaces. If desired, or if local codes mandate the use of an air kit, then an AKU1 is required . If the outside air kit is to be used, the AKU1 MUST be installed BEFORE the fireplace is enclosed.
  • Page 13 (4 required) Size of roof hole varies with the type of chimney termina- tion installed. Refer to installation instructions provided with Vermont Castings Group chimney termination to find correct size of roof hole. Attic Joist There must be a 1¹⁄₂ (38 mm) air space between outermost portion of chimney sections and any adjacent combustible surfaces.
  • Page 14: Finishing

    Space requirements for your city or state. NOTE: Other building to Sides materials may be required in addition to Vermont Castings Group Firestop Spacers. Finishing CAUTION: All joints between the finished wall and the 0"...
  • Page 15 ODSR Series "A" Outdoor Woodburning Fireplace Mantel Clearance - Mantel Clearance - with Noncombustible Facing Material No Noncombustible Facing Material Combustible Mantel 12" 12" Combustible Mantel and Trim (305mm) and Trim (305mm) Finished Wall Finished Wall Max. Max. 1¹⁄₂" 1¹⁄₂" Header Header (38mm)
  • Page 16: Side Wall Protection

    Figure 24 of fireplace opening dimensions and mounting detail. must be protected with Vermont Castings Group Wall Shield Model SP40 or a specifically built wall shield described NOTE: hearth Extension must not cover the air inlet below.
  • Page 17 ODSR Series "A" Outdoor Woodburning Fireplace Side View COMMON MATERIALS AND FACTORS Wall Covering MINIMUM MATERIAL THICKNESS Noncombus- 2 x 4 Header EH2416 tible Decorative (Do not notch 0.458 1.09 0.50 in.** Facing (MHSC) at standoffs) Seal all cracks between fireplace sur- Common Brick 0.10 5.46 in.**...
  • Page 18: Installing Line For Gas Logs

    Vermont Castings Group fireplaces are designed to ac- cept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (Vermont Castings Group manufactures a 1" wide variety of gas logs for use in Vermont Castings Group Min. Supply Line Gas Line Fireplaces.)
  • Page 19: Replacement Parts

    ODSR Series "A" Outdoor Woodburning Fireplace 6811 Vermont Castings Group reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODSR36A/42A Outdoor Woodburning Fireplace Item/Model Number ODSR36A ODSR42A 1. Damper Weld Assembly...
  • Page 20: Accessories

    ODSR Series "A" Outdoor Woodburning Fireplace Accessories The following accessories for this appliance are available from your local Vermont Castings Group distributor. Should you need additional information beyond what your distributor can furnish, contact: Vermont Castings Group, 149 Cleveland Drive, Paris, KY 40361, Attn: Technical Services.
  • Page 21: Chimney Components

    ODSR Series "A" Outdoor Woodburning Fireplace Chimney Components U.S. Component Description Model Number Round Top Termination Top used to terminate chimney at roof. RLTSK8 (Flashing not included.) Round Top Termination - Top used to terminate chimney at chase. RLTSK8L Extended (Flashing not included.) Flashing Metal finishing required around Contemporary...
  • Page 22 ODSR Series "A" Outdoor Woodburning Fireplace (Chimney Components con't.) Canada Component Description Model Number Chimney Collar Enclosure Installs on the "over the chimney collar" of the CCE-SK fireplace; provides outside air to assist in cooling the chimney system. Attic Insulation Shield Used to prevent insulation from coming in AIS-SK contact with the chimney system.
  • Page 23: Warranty

    Limitations and Exclusions 1. No one has authority to add to or vary this limited warranty, or to create for Vermont Castings Group any other obligations of liability in connection with this fireplace and accessory.
  • Page 24 Vermont Castings group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...