IBM InfoPrint 20 User Manual page 107

Hide thumbs Also See for InfoPrint 20:
Table of Contents

Advertisement

2. For more information about configuring the twinax attachment, see IBM Network
3. If you are unfamiliar with using the operator panel to work with menus, please
Twinax Setup Menu
Item
SCS ADDR
OFF*
n
IPDS ADDR
OFF*
n
EDGE-EDGE
OFF*
ON
BUFFERSIZE
1024*
256
Printers: Twinax/Coax Configuration Guide.
read "Using the Operator Panel Keys" on page 16 and "Navigating Menus" on
page 17 before continuing.
Value
The twinax hardware address of the SCS port. n can be from 0 to 6.
Notes:
1. SCS ADDR and IPDS ADDR cannot be set to the same value.
2. If you change SCS ADDR or IPDS ADDR, you must power off
the printer, wait ten seconds, and then power on the printer for
the new value to take effect.
3. When the IPDS SIMM is installed, the InfoPrint 20 can act as
two separate printers on the same twinax port. (The printer
cannot be attached to two different twinax systems using the
same twinax card.) One "printer" prints SCS data to one address
(SCS ADDR), and the other prints IPDS to another address
(IPDS ADDR).
The twinax hardware address of the IPDS port. n can be from 0 to
6.
Notes:
1. SCS ADDR and IPDS ADDR cannot be set to the same value.
2. If you change SCS ADDR or IPDS ADDR, you must power off
the printer, wait ten seconds, and then power on the printer for
the new value to take effect.
3. When the IPDS SIMM is installed, the InfoPrint 20 can act as
two separate printers on the same twinax port. (The printer
cannot be attached to two different twinax systems using the
same twinax card.) One "printer" prints SCS data to one address
(SCS ADDR), and the other prints IPDS to another address
(IPDS ADDR).
Turns edge-to-edge printing on or off.
v OFF—the printer maintains a no-print border of 4 mm on all four
paper sides.
v ON—The printer allows printing up to the physical page size.
Notes:
1. To avoid toner contaminating the printer, IBM recommends
leaving EDGE-EDGE set to OFF for twinax printing; use ON only
when necessary.
2. The Twinax Setup Menu item EDGE-EDGE applies to SCS data
only. To specify edge-to-edge printing for IPDS data, use the
EDGE-EDGE item on the IPDS Menu.
Specifies the IPDS buffer size in bytes. The SCS buffer size is
always 256.
Description
Chapter 6. Operator Panel Menus