Check the appliance is electrically safe and gas sound when you have finished.

Electrical Connection

The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (Fig. 7.8 and Fig. 7.9). Check that the links are correctly
fitted and that the terminal screws are tight. Secure the mains
cable using the cable clamp.

Final Checks

Hob Check
Check each cooking zone in turn. Be sure to use pans of the
correct size and material.
Grill Check
Turn on the grill control and check that the grill heats up.
Oven Check
Set the clock as described earlier, and then turn on the ovens.
Check the oven fans start to turn and that the ovens heat up.

Final Fitting

Fitting the Plinth
Loosen the 3 screws along the front bottom edge of the
cooker. Twist and fit each end keyhole over their respective
screws. Tighten the fixing screws (Fig. 7.10).

Customer Care

Installer: Please complete your details in this guide, inform
the user how to operate the cooker and hand over the
instructions.
WARNING! Refer to Before You Start... chapter.
31
Current Operated Earth Leakage Breakers
The combined use of your induction cooker and other
domestic appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
ArtNo.350-0012 - Securing the plinth
Fig. 7.8
6 mm² max
Fig. 7.9
6 mm² max
10 mm² max
Fig. 7.10