Vent Configurations With Horizontal Termination (Dancing/Diamondfyre) - Travis Industries 564 HO NB GSR2 Installation Manual

(with screen)
Hide thumbs Also See for 564 HO NB GSR2:
Table of Contents

Advertisement

28

Vent Configurations with Horizontal Termination (Dancing/DiamondFyre)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°) may be used.
Only one horizontal elbow may be used.
NOTE: With no vertical rise, LP installations have a maximum run of 2 feet (0.6m); NG installations have a
maximum run of 4 feet (1.2m).
21' max (6.4m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
Travis Industries
Installation
(
Exhaust Restrictor #4
Intake Restrictor #5
Diffuser Position #2 (OPEN)
Exhaust Restrictor #1
Intake Restrictor #1
Diffuser Position #1 (CLOSED)
2' LP/4' NG Maximum
H2
.
H1
for qualified installers only)
Exhaust Restrictor # 5
Exhaust Restrictor #4
Intake Restrictor #3
Diffuser Position #2 (OPEN)
Exhaust Restrictor #3
Intake Restrictor #2
Diffuser Position #2 (OPEN)
Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a vertical elbow.
4150330
28
21' max (6.4m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01408

Advertisement

Table of Contents
loading

Table of Contents