Complete the following steps to replace a hot-swap power supply:
1. Review the safety information beginning on page 95 and "Installation guidelines"
on page 43.
2. Remove the server bezel (see "Removing the bezel" on page 45).
3. If your server has only two power supplies installed, turn off the server (see
"Turning off the server" on page 9).
4. Press the orange release lever on the selected power supply; then, pull the
power supply out of the bay and set it aside.
Handle (open
position)
LED
5. Make sure the power-supply handle is in the open position; then, slide the
power supply all the way into the chassis before placing the power-supply
handle into the locked position.
Handle (open
position)
LED
6. If the server is not turned on, turn on the server (see "Turning on the server" on
page 8).
7. Verify that the ac power LEDs on the server and the PS dc power LEDs on
each power supply are lit, indicating that power supplies are installed and
operating properly.
8. Replace the server bezel (see "Replacing the bezel" on page 47).