Wide-Angle Flaps, Diffuser, Louveres And Autoswing - Daikin FTK25JVE9 Service Manual

Inverter pair ftk(x)-j / rk(x)-j series
Hide thumbs Also See for FTK25JVE9:
Table of Contents

Advertisement

Si04-115
1.6

Wide-angle Flaps, Diffuser, Louveres and Autoswing

Outline of the
It can be commanded for J type by means of a user setting to select either any one desired
position among the five-step directions of air flow adjusted on a remote controller, or Auto-
action
swing.
Although the liquid crystal display of the five-step directions of the air flow is common for the
modes of Cooling·Dry/Heating as illustrated above, in fact the range of the swing angle is
slightly different in every operation mode.
The position a user set will be selected among the five positions calculated through the
preliminary and evenly divided into four partitions which were taken from the upper and lower
flap angle's range limits of each mode.
When Auto-swing is chosen, the flap swings in the swing range which meets the operation
mode selected.
0 degree based on
the horizontal line.
20˚
"
Others
Main Function
Heating mode
0 degree based on
the horizontal line.
45˚
(R1903)
The vertical louver can be adjusted manually. The movable range is 60 degrees for left or
right, and total 120 degrees.
5
4
3
2
1
Initial
Cooling /Dry mode
25˚
(R1904)
∗ Fan mode is available for the models of cooling-only.
General Functionality
(R1902)
0 degree based on
the horizontal line.
10˚
Fan mode
45˚
(R1905)
25