Inverter pair ftk(x)-j / rk(x)-j series
Hide thumbs Also See for FTK25JVE9:
Table of Contents

Advertisement

Si04-115
Frequency controlled functions
The following table shows the different functions, which are controlled by decreasing or
increasing the frequency:
Sensor
Function
Thermistor
Low
outdoor ambient
outdoor
thermistor (R1T)
temperatur
e control
" outdoor
High
pressure
temperature
limitation in
thermistor
heating
(R1T)
" indoor heat
exchanger
thermistor
(R2T)
Freeze-up
indoor heat
prevention
exchanger
thermistor (R2T)
Peak cut off indoor heat
exchanger
thermistor (R2T)
Main Function
Why?
How?
To avoid condensation
By setting a
in cooling mode.
high frequency
limit.
This control
is not executed when
the unit is in forced
cooling mode or in test
mode.
To control the pressure. By setting a
high frequency
limit.
To prevent the freezing
By setting a
up of the indoor unit in
high frequency
cooling mode.
limit.
To prevent an abnormal
By setting a
high temperature on the
high frequency
indoor heat exchanger
limit.
in heating mode.
Set
Reset
T
<
T
outdoor ambient
outdoor ambient
18°C
25°C
" heating mode
" compressor stop
" T
" timer delay (70 s)
> 16 °C
outdoor
" T
has passed
indoor heat
> 22 °C
exchanger
" compressor on
" during cooling
T
indoor heat exchanger
" 0 °C <
> 8 °C for 2
T
seconds
indoor heat
< 8 °C
exchanger
" during heating
T
indoor heat exchanger
" 50 °C <
< 50 °C for 2
T
seconds
indoor heat
< 67 °C
exchanger
General Functionality
Malfunction
>
T
indoor heat exchanger
< 0 °C
(result: compressor
stop)
T
indoor heat exchanger
> 67 °C
(result: compressor
stop)
19