Daikin FTK25JVE9 Service Manual page 52

Inverter pair ftk(x)-j / rk(x)-j series
Hide thumbs Also See for FTK25JVE9:
Table of Contents

Advertisement

Si04-115
Installation
Do not attempt to install the air conditioner
by yourself.
Consult the service shop or a qualified
technician.
Incorrect work will result in water leakage,
electric shocks or fire. For installation, consult
the service shop where you bought the unit or
a qualified technician.
Do not connect the air conditioner to a
power supply different from the
specification.
It may cause trouble or fire.
Do not install the air conditioner in places
where flammable gas may leak.
If leaked gas should accumulate near the unit,
fire may occur.
Installation site
To install the air conditioner in the following types of
environments, consult the shop.
l
Places with an oily ambient or where steam or soot occurs.
l
Salty environment such as coastal areas.
l
Places where sulfide gas occurs such as hot springs.
l
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of
good drainage.
Consider nuisance to your neighbours from noises.
For installation, choose a place as described below.
l
A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.
l
A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours.
Electrical work
l
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
System relocation
l
Relocating the air conditioner requires specialized knowledge and skills. Please consult the shop where you
bought the air conditioner if relocation is necessary for moving or remodeling.
System Configuration
WARNING
The air conditioner must be earthed.
Incomplete earthing may result in electric
shocks.
Do not connect the earth line to a gas pipe,
water pipe, lightening rod, or a telephone
earth line .
CAUTION
Depending on the environment, an earth
leakage breaker must be installed.
Lack of an earth leakage breaker may result in
electric shocks.
Arrange the drain hose to ensure smooth
drainage.
Incomplete drainage may cause wetting of the
building, furniture etc.
A place
with good
ventilation
Wall
Air
outlet
l
For efficient operation, take as large
spaces around the unit as site allows.
Instruction
To prevent inter-
ference, place it
at least 1 m away.
Air
inlet
3
(R1925)
43