AIR INDUCTION SYSTEM
1
EAS00510
CHECKING THE AIR INDUCTION SYSTEM
1. Check:
8 hoses
Loose connection
Cracks/damage
8 pipe
Cracks/damage
2. Check:
8 air cut-off valve
Cracks/damage
NOTE:
When the negative pressure is applied to the
part 1, check that the continuity in the direction
of arrow mark is completely lost. If the negative
pressure is not loaded, the continuity can be
obtained.
7-13
CARB
Connect properly.
Replace.
Replace.
Replace.