Transfer section

(1) Detaching and refitting the transfer belt unit
Follow the procedure below to replace the transfer belt unit.
Procedure
1. Remove the fuser unit (see page 1-5-41).
2. Remove two screws and then remove the
left eject ass'y.
Caution in installation of left eject ass'y
Take care not to damage the sensor and the light
shielding plate of actuator.
And also check the operation of the actuator after
installing to see if the actuator operates correctly.
Screw
Left eject ass'y
Sensor
1
2
Light
shielding
plate
Sensor
3
Sensor
2JZ/2JX/2JV/2H7-1
Screw
Actuator
Left eject ass'y
Light
shielding
plate
Figure 1-5-63
Actuator