2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Checking/clearing the fuser count
U167
Description
Displays and clears the fuser count for checking.
Purpose
To check or clear the fuser count after replacement of the fuser unit. Also to clear the counts after replacing
unit.
Method
1. Press the start key. The fuser count is displayed.
Display
Fixing Counter
Clearing
1. Press [Clear Counter].
2. Press the start key. The count is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Displaying fuser heater temperature
U199
Description
Displays the detected fuser temperature.
Purpose
To check the fuser temperature.
Method
1. Press the start key. The current setting is displayed.
Display
HEAT EDGE TEMP
HEAT CENTER TEMP
PRESS TEMP*
*: 40/40, 50/40 ppm model only.
Completion
Press the stop key. The screen for selecting a maintenance mode No. is displayed.
Turning all LEDs on
U200
Description
Turns all the LEDs on the operation panel on.
Purpose
To check if all the LEDs on the operation panel light.
Method
1. Press the start key.
2. Select [ALL LED ON]. All the LEDs on the operation panel light.
3. Press the stop key. The LEDs turns off.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-84
Description
Description
Fuser count value
Description
Heat roller edge temperature (
Heat roller center temperature (
Press roller center temperature (
C)
C)
C)