Separate DHW cylinder for the Vitoladens 300-W
3.3 Vitocell 100-W, adjacent (type CVA – 160 to 300 litre, white finish) made from steel with
Ceraprotect enamel coating
■ Adjacent
■ made from steel, with Ceraprotect enamel coating and internal indirect coils
(for further technical details, see the separate datasheet for the Vitocell 100-V)
Capacity
DIN register no.
Connections
Heating water flow and return
DHW and cold water
DHW circulation
Permiss. operating pressure
– heating water side
– DHW side
Permiss. temperatures
– heating water side
– DHW side
Standby heat loss q
at 45 K tempera-
3
BS
ture differential (actual values to
DIN 4753-8)
Dimensions
Length c (7)
Width a
Height k
Weight
VA
BÖ
k
b
BÖ
Inspection and cleaning aperture only for 300 litre capacity.
E
Drain
HR
Heating return
HV
Heating flow
KW
Cold water
VIESMANN
16
l
R
R
R
bar
bar
°C
°C
kWh/24 h
mm
mm
mm
kg
WW
Z
HV/SPR
HR
KW/E
(cont.)
160
0241/06-13 MC/E
1
¾
¾
25
10
160
95
1.50
581
605
1189
86
SPR
b
SPR Sensor well for cylinder temperature sensor or control thermo-
stat
WW DHW
Z
DHW circulation
VITOLADENS 300-W/VITOLADENS 333-F
200
300
1
1
¾
1
¾
1
25
25
10
10
160
160
95
95
1.70
2.20
581
633
605
705
1409
1746
97
151