Vitocell 100-U and 100-W, type CVU
Enamelled DHW cylinder with internal
indirect coils for DHW heating in con-
junction with solar heating systems,
freestanding and wall mounted boilers
and/or EHE immersion heater for
dual-mode operation.
&
DHW cylinder, fully equipped with
Solar-Set, comprising:
– Solar-Divicon
Connections
A Connection for thermometer sen-
sor
4
– Vitosolic 100
– Pre-assembled pipework
&
Content: 300 litres
&
Suitable for systems conforming to
DIN 1988, DIN EN 12828, DIN 4753
&
DIN registration number: Applied for
&
Vitocell 100-W: in white, otherwise
identical
B Magnesium anode with earth
cable
C Heating water return, solar (lower
indirect coil)
D Hot water to the pipework
E Heating water flow, solar (lower
indirect coil)
F Sensor well for cylinder tempera-
ture control
G Heating water flow, boiler (upper
indirect coil)
H DHW circulation
K Heating water return, boiler
(upper indirect coil)
L Cold water/drain
M Heating water return, solar (lower
indirect coil)/sensor well for cylin-
der temperature sensor, solar
N Sensor well for lower thermometer
O Heating water flow, solar (lower
indirect coil)
P Female connection for immersion
heater