Design information
Sizing the oil line
Suction head H in m max. cable length in m when the suction
line has the following diameter:
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
0.0
-0.5
-1.0
-1.5
-2.0
-2.5
-3.0
-3.5
-4.0
5
VIESMANN
50
(cont.)
6x1 mm
8x1 mm
100
100
95
100
89
100
83
100
77
100
71
100
64
100
58
100
52
100
46
100
40
100
33
100
27
100
21
100
15
75
9
44
12
A total pressure drop of 0.35 bar is assumed, based on fuel oil EL with
6.0 cSt (DIN 51603-1) including 1 shut-off valve, 1 foot valve and 1 fuel
oil filter.