5. Remove the screw (C) securing the carrier motor bracket to the
bottom cover.
6. Disconnect the printhead cable from the logic board and move it
back and out of the way, as shown.
7. Remove the five screws (D) securing the carrier motor bracket
to the print unit.
8. Remove the Home Position sensor (E) from the top of the
carrier motor bracket by pinching the clips underneath the
bracket.
9. Remove the carrier motor bracket from the print unit by pulling
up and out on the rubber grommet (F) between the motor
bracket and the bottom cover.
10. Disconnect the carrier motor cable from the logic board.
11. Remove the carrier motor from the motor bracket.