SAFETY INSTRUCTION FOR MANUAL CONTROL (SPK) AND HI/LO CONTROL (CVTHL)

FOR YOUR SAFETY READ BEFORE LIGHTING

A. BEFORE OPERATING smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not attempt to light any appliance.
Do not touch any electric switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
B. Use only your hand to push in, or turn the gas
control knob. Never use tools. If the knob will
not push in or turn by hand, don't try to repair
MANUAL CONTROL LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully
open.
3. Push in gas control knob slightly and turn
clockwise
to "OFF."
noTE: Knob cannot be turned to "oFF"
unless knob is pushed in slightly.
4. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow "B" in the safety information
label. If you don't smell gas, go to next step.
5. Find pilot — follow metal tube from gas con-
trol.
6. From "OFF" position, push
gas control knob slightly
and turn counterclockwise
to "PILOT." Push
control knob for 5 seconds.
1. Push in gas control knob slightly and turn clock-
wise
to OFF position. Do not force.
16
OPERATING INSTRUCTIONS FOR SPK AND CVTHL KITS
i n
i n
Control Knob
LG905
TO TURN OFF GAS TO HEATER
pilot knob
If you do not follow these instructions
exactly, a fire or explosion may result
causing property damage, personal injury
or loss of life.
it. Call a qualified service technician. Force or
attempted repair may result in a fire or explo-
sion.
C. Do not use this appliance if any part of it has
been under water. Immediately call a qualified
service technician to inspect the appliance and
to replace any part of the control system and
any gas control that has been under water.
7. With the control knob pushed in, immediately
light the pilot with a match. Continue to hold the
control knob in for about one (1) minute after
the pilot is lit. Release knob and it will pop back
up. Pilot should remain lit. If it goes out, repeat
steps 5 through 9.
• If knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.
• If the pilot will not stay lit
after several tries, turn the
gas control knob to off and
call your service technician
or gas supplier.
8. Turn gas control knob counter-
clockwise
to "ON."
Manual Pilot