FLAME APPEARANCE

CHECKING BURNER FLAMES
Flame should be yellow and extend vertically
(not curling toward fireplace screen).

PILOT FLAME APPEARANCE

The pilot flame must always be present when appliance is
operating. It should just touch the top of the thermocouple/
thermopile tip.
During manufacturing, fabricating, and shipping, various
components of this appliance are treated with certain oils,
films, or bonding agents. These chemicals are not harm-
ful, but may produce annoying smoke and smells as they
burn off the first time the appliance is used. Operate the
appliance 2 to 3 hours at the highest setting to burn off all
the oils, films, etc. Never use this appliance with glassed
doors closed. This could cause the pilot to go out and
severe sooting outside the fireplace. Always operate this
appliance with the fireplace screens in place.
27D8851
Ember bed should have
a yellow/orange glow
VWFST Series Vented Gas Log Set
Figure 21 -
Flame Appearance
LG1064
VWFST log flames
Figure 22 -
Pilot Flame Appearance
LG910
SPK Pilot flame
LG1064
Thermocouple/
Thermopile Tip
LG910