6.3.3

Timing Chart

(1) Data input and printing timing
6.3.4

Data Receiving Control

When the BUSY signal is at "LOW," the printer can receive the data from the host, but when at "HIGH," it
cannot.

7. SERIAL INTERFACE

7.1 Specifications

(1) Synchronous system: Asynchronous
(2) Baud rate: 150, 300, 600, 1,200, 2,400, 4,800, 9,600, or 19,200 bps (User selectable)
(3) Configuration of one word
•Start bit
•Data bits
•Parity bit
•Stop bit
: 1 bit
: 7 or 8 bits (User selectable)
: Odd, even, or none (User selectable)
: 1 bit or more
T1, T2, T3 : 0.5 µs MIN
T4
: 270 ns MAX
: 2.3 µs TYP
T5
T6
: 500 ms MIN (At power-on)