Tcm Error Messages - Symbol MC50 User Manual

Hide thumbs Also See for MC50:
Table of Contents

Advertisement

TCM Error Messages

TCM validates the cells in the partition table when the Execute button is clicked. Cells highlighted in red contain an error. Partition
loading is disabled until all errors are corrected.
Error
Failed to build images: flash file
system DLL not loaded!
Failure finding directory xxx
Failure creating volume
Failure adding system file to image
INVALID PATH
Nothing Selected To Build
Illegal ESS ID
Disk Full
Target Disk Full
Hex file is READ ONLY
Error opening the file xxx with write
access
Failure creating binary file
Hex File To load is missing or invalid
Could not locate mobile computer
name in TCM.ini file
Incorrect disk sizes in TCM.ini file
INVALID DIRECTORY
One of the disk sizes is one sector in
size
INVALID VOLUME NAME
Corrupt TCM.INI file! (Invalid value of
VolumeDivisor)
Invalid version of TCM script file
Corrupt or missing TCM.ini file
FAILED CONNECTION TO COM PORT
(Could not get status)
FAILED CONNECTION TO TERMINAL
(Terminal Not Connected Properly/
Terminal Not Ready to Receive)
Table 6-4. TCM Error Messages
TCM could not load the DLL required to build images for the targeting flash file system. Reinstall TCM or recover the
DLL.
Building process failed because directory xxx was not found.
Building process failed because a certain disk volume could not be created.
Build process failed because TCM failed to add a certain system file to the disk image.
The path for the image file to build is not valid.
In the Config Build window, no item is selected to build.
In the Build ESSID Partition window, no ESS ID was entered or the ESS ID entered was illegal.
TCM failed to create Hex image file at the selected path. Check available disk space.
Build process failed because TCM failed to add file to the image of a disk volume. Remove some files or increase the
disk size.
The Hex image file to be created exists and is read-only. Delete the existing file or change its attribute.
TCM could not open file xxx with write access. Check if file is in use.
TCM failed to open/create an intermediate binary file.
In Load Terminal window, the file selected to load has invalid status.
While loading the Script Properties window, TCM could not find the TCM.ini section corresponding to the terminal type
specified by the current opening script. Either TCM.ini or the script file is invalid.
The total disk size specified in the script does not match the total disk size defined in the corresponding TCM.ini section.
Check if the script is corrupt or the TCM.ini has changed after the script was created.
In Script Properties window, the selected System File Path is not a valid directory.
In Script Properties window, one of the disks is too small (one sector in size). This may cause problem while building
images, especially when cushion is enabled. Increase the disk size.
In Script Properties window, one of the volume labels is not valid.
The VolumeDivisor entry is missing or invalid in the TCM.ini. Reinstall TCM or recover TCM.ini.
The TCM script was not created by this version of TCM.
TCM could not find TCM.ini file.
While downloading images to mobile computer, TCM failed to connect to the selected COM port. Check if the COM port
is free and is properly configured.
While downloading images, TCM failed to connect to the mobile computer. Check if the correct flow control protocol is
selected and the mobile computer is properly connected and is in a listening state.
Creating and Loading Hex Images 6-15
Description/Solution

Advertisement

Table of Contents
loading