Control Circuit Configuration - Toshiba MM-A0280HT Service Manual

Modular multi split type system
Hide thumbs Also See for MM-A0280HT:
Table of Contents

Advertisement

(1) LED display on indoor P .C. board – MCC-1361-01
General type
Part No.
D13
D11
D22
D51
Indoor P .C. board parts layout
13

Control Circuit Configuration

Indoor Units
Colour
Displayed content
Orange
Serial receive
Green
Serial send
Red
Alarm stop display
Yellow
Cycle communication
D22 (Red)
MCC-1361-01
PCB identification code
(MCC-1361-01)
Details
Flashes synchronized with the receive
signal to the standard remote controller.
Flashes synchronized with the send signal
from the standard remote controller.
Goes on when the indoor unit stops
with fault.
Flashes synchronized with receive signal
from the outdoor unit.
D13 (Orange)
D51 (Yellow)
50
D11 (Green)

Hide quick links: