Summary of Contents for Toshiba MMY-MAP0804FT8-E

  • Page 1 AIR CONDITIONER (MULTI TYPE) Owner’s Manual Outdoor Unit For commercial use Model name: MMY-MAP0804FT8-E MMY-MAP1004FT8-E MMY-MAP1204FT8-E MMY-MAP1404FT8-E MMY-MAP0804FT8Z-E MMY-MAP1004FT8Z-E MMY-MAP1204FT8Z-E MMY-MAP1404FT8Z-E MMY-MAP0804FT8ZG-E MMY-MAP1004FT8ZG-E MMY-MAP1204FT8ZG-E MMY-MAP1404FT8ZG-E English...
  • Page 2: Table Of Contents

    Contents Original instruction Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conditioner. 1 Precautions for safety ..........3 •...
  • Page 3: Warning Indications On The Air Conditioner Unit

    • The qualified installer is a person who installs, maintains, relocates and removes the air conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations.
  • Page 4: Precautions For Safety

    – 3 – Precautions for safety • When the air conditioner is used in a closed room, be careful of sufficient ventilation of the room. Poor ventilation causes oxygen shortage. • Do not expose your body to cool air directly for a long time and do not cool yourself excessively. The manufacturer shall not assume any liability for the damage caused by not observing the description of this Doing so may result in deteriorated physical condition and ill health.
  • Page 5 • Check whether the installation base and other equipment have become deteriorated after being used for a long time. Leaving them such condition may result in the unit’s falling down and causing injury. • Do not leave flammable sprays or other flammable materials near the air conditioner, and do not spray flammable aerosol directly to the air conditioner.
  • Page 6: Part Names Of Outdoor And Indoor Units

    – 5 – Part names of outdoor and indoor units Connectable indoor units Model type Model Name Outdoor unit 4-way cassette MMU-AP✽✽✽✽H✽ Compact 4-way cassette MMU-AP✽✽✽✽MH✽ 2-way cassette MMU-AP✽✽✽✽WH✽ Air discharge Warm air comes out when cooling, and cool MMU-AP✽✽✽✽YH✽ 1-way cassette air when heating.
  • Page 7: Way Cassette Type

    ◆ 2-way Cassette Type ◆ Concealed Duct Standard Type MMD-AP✽✽✽4H✽ Earth screw Equipped on the electrical control Return air grille Earth screw box. Air in the room is taken in through here. Equipped on the electrical control box. Air discharge The air discharge duct is connected.
  • Page 8: Ceiling Type

    – 7 – ◆ Slim Duct Type ◆ Floor Standing Concealed Type Drain funnel (with strainer) Earth screw Accessory to be attached at the site Equipped on the electrical control box. Return air grille Air discharge The return air duct is Air filter connected.
  • Page 9: Part Names And Functions Of The Remote Controller

    Part names and functions of the remote controller This remote controller can control up to 8 indoor units. Display section All indicators are displayed in the display example below. Actually, only the selected options will be displayed. Display • blinks on the display of the remote controller the first time the power section switch is turned on.
  • Page 10: Operation Section

    – 9 – Operation section Once the settings have been configured, all you need to do is push the button from then on. UNIT LOUVER button (Unit/Louver select button) Selects a unit number (left) and louver number (right). button (Fan speed select button) Operation lamp UNIT button: Selects the desired Fan speed.
  • Page 11: Basic Operation

    Basic operation Changing the set temperature Power save operation Push the “TEMP. ” buttons. • When you use the air conditioner for the first time or change the settings, follow the procedures below. Push to increase the temperature, and From next time, pushing the button starts running of the air conditioner with the chosen settings.
  • Page 12: Timer Operation

    – 11 – Timer operation Installation Select a timer type from the following three: (Max. 168 hours) Location Be careful of operation OFF timer : Stops running after the specified period. Repeat-OFF timer : Stops running after the specified period every time you use the air conditioner. sounds •...
  • Page 13: Notes On Operations And Performance

    Notes on operations and performance Cooling / Heating operations • When the outdoor temperature goes out of the operable range, cooling or heating operation may not Check before operation Protective device be performed in order to protect the equipment. In (High pressure switch) this case, “...
  • Page 14: Louver Direction

    – 13 – ◆ To stop swinging Louver direction 4-way cassette type only SWING/FIX Push the button at the desired 4-way cassette type, 2-way position while the louver is swinging. NOTE ◆ To set the louvers individually SWING/FIX cassette type, 1-way cassette •...
  • Page 15 ◆ Setting the louver lock ▼ Cyclic swing (Recommended for cooling) SWING/FIX Push the button to confirm the Push the button. direction of the selected louver. All four louvers swing at different times like waves. Push the button to finish the setting. UNIT LOUVER Push and hold the button (right side of...
  • Page 16 – 15 – ◆ Releasing the louver lock Push the button to finish the setting. 4-way cassette type 2-way cassette type Set “0000” in Step 4 of “Setting the louver lock”. ▼ When cooling ▼ When cooling mark disappears. Point the louver horizontally. Point the louver horizontally to send cool air across the entire room.
  • Page 17 Ceiling type 1-way cassette (YH series), NOTE NOTE and floor standing types To improve the cooling/heating performance, change 1. When sending air downward, bend the louvers Vertical adjustment the louver angle for each operation. evenly as shown in the following figure. If the air flow is blocked, water droplets may fall ◆...
  • Page 18 – 17 – ◆ Changing the air discharge 1-way cassette type Floor standing type Floor standing cabinet type (YH series) Follow the procedure below to change the air Vertical adjustment discharge: Vertical adjustment ▼ When cooling Remove the two fixing screws of the air Move the louver manually and point it horizontally to ▼...
  • Page 19: Tips For Saving Energy And Comfortable Performance

    Tips for saving energy and comfortable Maintenance performance WARNING To save energy and perform comfortable cooling and heating For daily maintenance including Air Filter cleaning, make sure to ask the qualified service person particularly following models as the maintenance requires high-place work; Clean the air filter often Do not cool/heat too much Do not attempt it by yourself.
  • Page 20: Periodic Inspection

    – 19 – ◆ Floor standing cabinet type Vacuum dust or brush clean. Cleaning the indoor unit and Before the cooling season • If heavily stained, it is more effective to wash in remote controller Push down the upper part of the return air lukewarm water mixed with neutral detergent.
  • Page 21: Troubleshooting

    Troubleshooting CAUTION When the following symptoms are found, check the points described below before asking repair servicing. If any of the following conditions occur, turn off the main power supply switch and immediately contact the dealer: • Switch operation does not work properly. Symptom Cause •...
  • Page 22: Specifications

    Cooling Heating 336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN MMY-MAP0804FT8-E MMY-MAP0804FT8Z-E Authorized Nick Ball MMY-MAP0804FT8ZG-E Representative/ Toshiba EMEA Engineering Director MMY-MAP1004FT8-E TCF holder: Toshiba Carrier UK Ltd. MMY-MAP1004FT8Z-E Porsham Close, Belliver Industrial Estate, MMY-MAP1004FT8ZG-E PLYMOUTH, Devon, PL6 7DB. MMY-MAP1204FT8-E United Kingdom...
  • Page 23 (Name of the manufacturer) TOSHIBA CARRIER CORPORATION 336 Tadehara, Fuji-shi, Shizuoka-ken (Address, city, country) 416-8521 Japan (Name of the Importer/Distributor in EU) Toshiba Carrier UK Ltd. Porsham Close, Belliver Industrial Estate, PLYMOUTH, (Address, city, country) Devon, PL6 7DB. United Kingdom EH99941299...