Self-Diagnostic Mode - Epson StylusPRO 7000 Service Manual

Color large format inkjet printer
Table of Contents

Advertisement

EPSON Stylus Pro 7000
Table 1-42. Maintenance Mode 2 - (NVRAM) counter value menu
LCD Message
HEAD LM
HEAD Y
CLEANER
Table 1-43. Maintenance Mode 2 - counter initialize menu
Message
Item
INIT. ALL
Exec
INIT. NVRAM
Exec
INIT. TIMER
Exec
INIT. CR MTR
Exec
INIT. PF MTR
Exec
INIT. HEAD
Exec
INIT. CLEANER
Exec
INIT. TTL PR
Exec
INIT. INK
Exec
INIT. WA. INK
Exec
CLR HEAD ERROR
Exec
Table 1-44. Maintenance Mode 2 - Adjustment/setup menu
LCD Message
BID OFFSET #1
BID OFFSET #2
Product Description
Item
Description
(decimal)
0~4294967295
Head unit (LM)
0~4294967295
Head unit (Y)
0~4294967295
Cleaning unit life value
.
Explanation
Initializes NVRAM, Timer, life counters,
and mechanical counters
Initializes NVRAM
Initializes timer
Initializes CR Motor counter (after
replacing ink tubes)
Initializes PF Motor counter
Initializes Head unit counter
Initializes cleaning unit counter
Initializes total print counter
Initializes ink counter
Initializes waste ink counter
Clear head error
Item
Description
Right head Bi-D offset setting
-4~0~+4
#1 (for Normal Dot 300cps)
Right head Bi-D offset setting
-4~0~+4
#2 (for Micro Dot 300cps)

SELF-DIAGNOSTIC MODE

Power-on button:
This mode is used primarily for replacing worn-out printer parts and
adjustment operations. For details, see Chapter 5, "Adjustment".
Service Requests
Paper Feed
+ Cut/Eject + Cleaning
Revision A
51

Advertisement

Table of Contents
loading

Table of Contents