3.13.3
Replacing the separation roller (Trays 1, 2, 3)
A. Periodically replaced parts/cycle
•
Separation roller: Every 1,000,000 prints (once for every 300,000 prints (tray 1, 2)/once for every 500,000
prints (tray 3) for actual replacement cycle)
B. Procedure
Note
• The replacement method of the separation roller assembly is the same for all the trays 1, 2 and 3.
The explanation here is made of the tray 1.
[2]
[1]
1.
Pull out the paper feed tray. (See "6.3.18 Remov-
[3]
[2]
ing/reinstalling the paper feed tray 1 and 2,"
"6.3.20 Removing/reinstalling the paper feed tray
3.")
2.
Bring up the pick-up roller assembly [1].
3.
Remove the 2 screws [2] and then remove the
entrance guide plate [3].
57gaf2c123na
3. PERIODIC CHECK
89