Battery Testing

1. Conduct a hydrometer test of the battery electrolyte:
IMPORTANT: Make sure the area around the cells is
clean before opening the battery caps.
A. Measure the specific gravity of each cell with a
hydrometer. Draw electrolyte in and out of the
hydrometer barrel prior to taking a reading to warm--
up the hydrometer. At the same time take the tem-
perature of the cell.
B. Temperature correct each cell reading. For each
10
F (5.5
C) above 80
o
o
specific gravity reading. For each 10
80
F (26.7
C) subtract 0.004 from the specific grav-
o
o
ity reading.
Example: Cell Temperature
Cell Gravity
ADD (20
Correction to 80
C. If the difference between the highest and lowest
cell specific gravity is 0.050 or greater or the lowest
cell specific gravity is less than 1.225, charge the bat-
tery. Charge at the recommended rate and time giv-
en in Charging or until all cells specific gravity is
1.225 or greater with the difference in specific gravity
between the highest and lowest cell less than 0.050.
If these charging conditions can not be met, replace
the battery.
2. Perform a high--discharge test with an adjustable
load tester.
This is one of the most reliable means of testing a battery
as it simulates the cold--cranking test. A commercial bat-
tery load tester is required to perform this test.
CAUTION
Follow the battery load tester manufacturer's
instructions when using a load tester.
A. Check the voltage across the battery terminals
prior to testing the battery. If the voltage is less than
12.0 VDC, recharge the battery before load testing.
B. Make sure the battery terminals are free of corro-
sion.
Electrical System
F (26.7
C) add 0.004 to the
o
o
F (5.5
C) below
o
o
100
o
1.245
o
above 80
o
F)
0.008
o
F
1.253
C. If the battery has been charged, apply a 150 amp
load for 15 seconds to remove the surface charge.
Use a battery load tester following the manufactur-
er's instructions.
D. Measure the temperature of the electrolyte in the
center cell.
E. Connect a battery load tester to the battery termi-
nals following the manufacturer's instructions.
Connect a digital multimeter to the battery terminals.
F. Apply a test load of 150 amps (one half the Crank-
ing Performance) for 15 seconds.
G. Take a battery voltage reading at 15 seconds,
then remove the load. Record this test voltage read-
ing.
F
H. Using the table below, determine the minimum
test voltage for the cell temperature reading.
Minimum
Test Voltage
9.6
9.5
9.4
9.3
9.1
8.9
8.7
8.5
I. If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.
Page 6 - - 36
Battery Electrolyte
Temperature
70
F (and up)
21.1
o
o
60
F
15.6
o
50
F
10.0
o
40
F
o
30
F
--1.1
o
20
F
--6.7
o
10
F
--12.2
o
0
F
--17.8
o
Workman MD/MDX
C (and up)
C
o
C
o
4.4
C
o
C
o
C
o
C
o
C
o