Power cable requirements—Indoor Dome
The following table shows the maximum cable
distance for several worst-case low line voltages
between various indoor power sources and the
indoor SpeedDome Optima. These distances are
for Sensormatic composite cables, which use 18
ac power wires.
AWG
This table applies to domes produced after October
of 2001; distances are much less for earlier domes.
Twisted Pair Adapter
The ADACTP01BNC Twisted Pair Adapter
(supplied) can be used to transmit video or video
with up-the-coax (UTC) dome control signals over
unshielded twisted pair (UTP) cables, point-to-
point, up to 300m (1000ft).
The adapter mounts directly to the video source or
receiver without additional cabling and uses
Category 2-6 twisted pair wires to transmit the
video and dome control signals. The adapter does
not require power.
One adapter is supplied. If used, another adapter
must be ordered to for the connection at the other
end of the cable. The figure below shows twisted
pair cable connections. See installation guide
8200-0298-01 for details.
American Dynamics
Dome Or
Fixed Camera
Cat 2-6 UTP Cable
Video Switcher/
Controller
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0181-01, REV. C)
Twisted Pair Adapter
(Dome End)
Twisted Pair Adapter
(Fixed Camera End)
Twisted Pair Adapter
(Switcher/Controller End)
4 of 14
Indoor Dome
AC Power Source
28 VA
Transformer
5604-0006-01
50 VA
Transformer
5604-0044-01
1-position SensorNet
RJ1SNUD
1-position SensorNet
RJ1SNUD-1
6-position SensorNet
Indoor J-Box
RJ6SN
Universal Transformer
0300-0914-01
Universal Transformer
0300-0914-03
Worst-Case
Meters
Low Line V
(Feet)
117
130 (425)
100
80 (250)
90
60 (200)
117
160 (525)
100
100 (325)
90
60 (200)
117
160 (525)
100
100 (325)
90
80 (250)
240
160 (525)
200
100 (325)
180
80 (250)
117
210 (675)
100
130 (425)
90
80 (250)
240
210 (675)
200
130 (425)
180
80 (250)
117
130 (425)
100
100 (325)
90
60 (200)
240
160 (525)
200
100 (325)
180
80 (250)

Advertisement