Mantel Clearances; Mantel Leg Clearances - Regency GEM54-NG Owner's Manual

Gem54 series gas fireplace
Hide thumbs Also See for GEM54-NG:
Table of Contents

Advertisement

INSTALLATION
Due to the extreme heat this fi replace emits, the
mantel clearances are critical. Combustible mantel
clearances from top of front facing are shown in the
diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the
paint may discolour.
Combustible mantel leg clearances as per diagram:
10

MANTEL CLEARANCES

14
12
10
30" (762mm)
0
(724mm)
To Floor

MANTEL LEG CLEARANCES

MANTEL LEG
Allowable mantel
leg projection
8
6
4
2
13" (330mm)
Drywall
3 ½" (89mm)
1" (25mm)
21"
20"
Top of
28-1/8"
Fireplace
Opening
4"
(102mm) Non-Combustible
1.5" (38mm)
11-1/2" (292mm)
14" (356mm)
15-3/4" (400mm)
Metal Stud
(On Edge)
Non-combustible
Facing
Standoff
Regency Gemfi re™ Gas Fireplace