Install Single Wall Connector and chimney system per manufacturer's written operating in-
4.
structions. See manufacturer's list of tested pipes in this manual.
COLLAR
COLLAR
3 SHEET METAL SCREWS
3 SHEET METAL SCREWS
CEILING
CENTER LINE
OF ELBOW
FLOOR PROTECTOR
B. Wall Exit Into Metal Tee-Box
1. Mark plumb line on the wall directly behind center of heater. (See Figure 6).
NOTE: When using 24# ga. minimum blue or black steel pipe, maintain 18" between pipe
and ceiling.
2. Place vertical portion of heater pipe and elbow in position and project a point onto plumb
line level with center of elbow.
Measure up so there will be at least 1/4" rise per foot of horizontal connector pipe,
3.
ROOF
CEILING
ATTIC
18" MIN.
WALL
Page 16
3 SHEET METAL SCREWS OR RIVETS
Figure 5
TEE BOX ASSEM.
CLEAN OUT ACCESS
"TEE" BOX ASSEM.
WALL PASS-THROUGH CONNECTOR
MARK PLUMB LINE
Figure 6