3-1 CTRL Setting
Here you can specify the amount of change produced by the three
knobs or by external MIDI controllers.
Turn the [VALUE] knob to access the desired screen. When you press
the [VALUE] knob, the setting can be edited. Use the [CURSOR]
buttons (left/right) to select the item that you want to edit.
The parameter controlled by the C1
3-1-1 C1:
knob
The parameter controlled by the C2
3-1-2 C2:
knob
The parameter controlled by the C3
3-1-3 C3:
knob
The parameter controlled when the
controller number specified by VC As-
3-1-4 VC:
sign is received
3-1-5
The parameter controlled when a
modulation message is received.
Modulation:
3-1-6
The parameter controlled when a
pitch bend message is received.
Pitch Bend:
3-1-7
The parameter controlled when an af-
tertouch message is received.
Aftertouch:
The function that will occur when a
3-1-8 Hold:
hold message is received.
* Larger values in the positive (+) or negative (-) direction will allow a
correspondingly greater change to occur.
* Changes you make to the sound using the controllers are temporary. They
do not rewrite the parameter values.
Pitch (Pitch depth)
Specifies the range of control over pitch. When using a knob, positive
(+) settings of this parameter allow you to raise the pitch by turning
the knob toward the right. With negative (-) settings, the pitch will fall
as you turn the knob toward the right.
Available Settings: -64–+63
* In order to vary the pitch in this way, you must turn on the pitch control
switch for the sample in V-Producer's Sample Edit screen (p. 62) in
addition to setting the depth here.
* The pitch bend change settings do not contain this parameter.
Time (Time depth)
Specifies the range of control over playback speed (time). When using
a knob, positive (+) settings of this parameter allow you to speed up
the playback by turning the knob toward the right. With negative (-)
settings, the playback will slow down as you turn the knob toward the
right.
Available Settings: -64–+63
* In order to vary the time in this way, you must turn on the time control
switch for the sample in V-Producer's Sample Edit screen (p. 62) in
addition to setting the depth here.
116
Formant (Formant depth)
Specifies the range of control over timbral character (formant). When
using a knob, positive (+) settings of this parameter allow you to
modify the timbral character so it approaches a "duck-like voice"
(smaller vocal cords) by turning the knob toward the right. With
negative (-) settings, the character will change toward a "giant-like
voice" (larger vocal cords) as you turn the knob toward the right.
Available Settings: -64–+63
* The formant can be controlled only for a sample whose encoding type (p.
55) is SOLO.
* In order to control the formant in this way, you must turn on the formant
control switch (p. 62) for the sample in addition to setting the depth here.
Level (Level depth)
Specifies the range of control over volume. When using a knob,
positive (+) settings of this parameter allow you to increase the
volume by turning the knob toward the right. With negative (-)
settings, the volume will decrease as you turn the knob toward the
right.
Available Settings: -64–+63
Default: 0
LFO Rate (LFO rate depth)
Specifies the range of control over LFO rate. When using a knob,
positive (+) settings of this parameter allow you to speed up the rate
by turning the knob toward the right. With negative (-) settings, the
rate will slow down as you turn the knob toward the right.
Available Settings: -64–+63
Default: 0
LFO Pitch (LFO pitch depth)
Specifies the range of control over how the LFO will affect the pitch
(Pitch LFO Depth). When using a knob, positive (+) settings of this
parameter allow you to change the Pitch LFO Depth in the positive (+)
direction by turning the knob toward the right. With negative (-)
settings, the Pitch LFO Depth will change in the negative (-) direction
as you turn the knob toward the right.
Available Settings: -64–+63
Default: 0
LFO Formant (LFO formant depth)
Specifies the range of control over how the LFO will affect the formant
(Formant LFO Depth). When using a knob, positive (+) settings of this
parameter allow you to change the Formant LFO Depth in the
positive (+) direction by turning the knob toward the right. With
negative (-) settings, the Formant LFO Depth will change in the
negative (-) direction as you turn the knob toward the right.
Available Settings: -64–+63
Default: 0
LFO Pan (LFO pan depth)
Specifies the range of control over how the LFO will affect the pan
(LFO Pan Depth). When using a knob, positive (+) settings of this
parameter allow you to change the LFO Pan Depth in the positive (+)
direction by turning the knob toward the right. With negative (-)
settings, the LFO Pan Depth will change in the negative (-) direction
as you turn the knob toward the right.
Available Settings: -64–+63
Default: 0