IBM System x3200 Type 4362 Problem Determination And Service Manual page 122

Ibm mini tower server problem determination and service guide
Hide thumbs Also See for System x3200 Type 4362:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 Types 4362 and 4363," on page 27 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
1801
A PCI adapter has requested memory
resources that are not available.
1802
No more I/O space is available for a PCI
adapter.
1803
No more memory (above 1 MB for a PCI
adapter).
1804
No more memory (below 1 MB for a PCI
adapter).
104
System x3200 Types 4362 and 4363: Problem Determination and Service Guide
Action
1. Make sure that no devices have been disabled in
the Configuration/Setup Utility program.
2. Change the order of the adapters in the PCI, and
PCI Express slots. Make sure that the startup
(boot) device is positioned early in the scanning
order. (For information about the scanning order,
see the User's Guide on the IBM System x
Documentation CD).
3. Make sure that the settings for the adapter and all
other adapters in the Configuration/Setup Utility
program are correct. If the memory resource
settings are not correct, change them.
4. If all memory resources are being used, remove
an adapter to make memory available to the
adapter. Disabling the BIOS on the adapter
should correct the error. See the documentation
that comes with the adapter.
1. If the error code indicates a particular PCI or
PCI-E slot or device, remove that device.
2. If the error remains, reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI adapter
b. (Trained service technician only) System
board
1. If the error code indicates a particular PCI or
PCI-E slot or device, remove that device.
2. If the error remains, reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI adapter
b. (Trained service technician only) System
board
1. Remove the failing adapter.
2. Reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI adapter
b. (Trained service technician only) System
board

Hide quick links: