v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 Types 4362 and 4363," on page 27 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Beep code
1-2-4
1-3-1
2-1-1
2-1-2
2-1-3
2-1-4
2-4-1
3-3-2
Description
RAM refresh verification failed.
First 64 K RAM test failed.
Secondary DMA register failed.
Primary DMA register failed.
Primary interrupt mask register failed.
Secondary interrupt mask register failed. (Trained service technician only) Replace the
Video failed; screen believed operable.
Critical SMBUS error occurred.
Action
1. Reseat the DIMMs.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only) System
board
1. Reseat the DIMMs.
2. Replace the lowest-numbered pair of
DIMMs with an identical known good pair of
DIMMs; then, restart the server. If the beep
code error remains, go to 3b. Return one
DIMM at a time from the failed pair to its
connector, restarting the server after each
DIMM, to identify the failed DIMM.
3. Replace the following components, one at a
time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only) System
board
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
system board.
(Trained service technician only) Replace the
system board.
1. Disconnect the power cord, wait 30
seconds, and retry.
2. Reseat the following components:
a. DIMM
b. System board
3. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMM
b. (Trained service technician only) System
board
Chapter 5. Diagnostics