12. Electrical Connections/Wiring Cont.
The zone valve micro
•
switch
must
connected
to
terminal block situated
next
to
the
control
panel
L
N
To fused spur
isolation switch
3
2
1
J
External controls
terminal block
120 VAC Control
Terminal Block
Figure 12.10
Route
the
electrical
•
supply
cord
and
external control cord as
illustrated in Fig. 12.12
Riva Plus Manual
12.5 Zone Valve Micro Switch Connection:
When connecting
•
be
the zone valve
the
switch, the jumper
J in Fig. 12.10
must be removed.
Zone
Valve
Power supply
terminal block
3
1
Figure 12.11
12.6 Finishing
•
the
To the external
control device
Figure 12.12
Room
Thermostat
V
T
N
L
120 VAC
Control Terminal
Block
To the fused spur
isolation switch
Connect
the
•
switch
of
the
valve to terminals 1
and 3 as shown in
figure 12.11
Connect
the
•
valve switch to the
room
thermostat
shown in figure 12.11
Lock the cords in place
•
with
the
flexible
clamps.
•
Replace the control panel
reversing the steps on
page
micro
zone
zone
as
cord
23.
31