12. Electrical Connections/Wiring Cont.
The zone valve micro
switch
must
connected
to
terminal block situated
next
to
the
control
panel
L
N
To fused spur
isolation switch
3
2
1
J
External controls
terminal block
120 VAC Control
Terminal Block
Figure 12.10
Route
the
electrical
supply
cord
and
external control cord as
illustrated in Fig. 12.12
Riva Plus Manual
12.5 Zone Valve Micro Switch Connection:
When connecting
be
the zone valve
the
switch, the jumper
J in Fig. 12.10
must be removed.
Zone
Valve
Power supply
terminal block
3
1
Figure 12.11
12.6 Finishing
the
To the external
control device
Figure 12.12
Room
Thermostat
V
T
N
L
120 VAC
Control Terminal
Block
To the fused spur
isolation switch
Connect
the
switch
of
the
valve to terminals 1
and 3 as shown in
figure 12.11
Connect
the
valve switch to the
room
thermostat
shown in figure 12.11
Lock the cords in place
with
the
flexible
clamps.
Replace the control panel
reversing the steps on
page
micro
zone
zone
as
cord
23.
31