Hardware Description
Ethernet Interfaces
The 7210 SAS-D provides 6 100/1000 SFP ports. Each port can be used for a direct connection to
a subscriber's Customer Premises Equipment (CPE), or as an uplink to another aggregation node.
The 7210 SAS-D also provides 4 10/100/1000Base-T fixed copper ports.
Console Port
The console port uses an RJ-45 connector with serial pinouts (see
connection to a terminal for performing switch monitoring and configuration operations. The
terminal may be a PC or workstation that is running terminal emulation software, or a terminal
configured as a Data Terminal Equipment (DTE) connection. A null-modem wired serial cable is
supplied with the switch for connecting to this interface.
The serial port configuration requirements are as follows:
• Default Baud rate – 115200 bps
• Character Size – 8 Characters
• Parity – None
• Stop bit – One
• Data bits – 8
• Flow control – none
Alarms
When your system has a major alarm, the CPU will turn the status LED amber. Currently, the
system provides an alarm for the following event:
•
Air Ventilation
7210 SAS-D does not have fan. Operators must allow for at least three inches of clearance on all
sides of the device to ensure proper airflow intake cooling system.
Page 22
Chassis temperature threshold exceeded - Major alarm is raised.
Table
7210 SAS-D Installation Guide
11) that enables a