A.O. Smith POWER VENT GAS Installation And Operating Manual page 44

Hybrid gas water heaters power vent gas models
Hide thumbs Also See for POWER VENT GAS:
Table of Contents

Advertisement

Available languages

Available languages

Fault
Code
Description
Displayed
E30
Blower Error.
E33
Water Flow Valve
Closed.
E34
Proportional Valve
(PV) Response
Too Slow.
E35
Repeated Flame
Loss Fault.
E36
Calibration error.
E37
No Water Flow.
E99
Board Failure.
Lockout types:
Continuous. Needs "Cycle the Power" or service to restart.
Soft. Will try to automatically recover and restart after 20 minutes.
Auto. Will automatically restart when voltage returns to acceptable parameters.
Alert. Will only display an error code in diagnostic mode.
44
Cause
Locked Rotor.
The water valve did not
open when attempting to
establish fl ow.
The closed loop control
of the proportional valve
is not functioning properly
(control error) or the valve
is responding slowly (valve
failure).
Low Gas Inlet Pressure.
Calibration sequence
incomplete because end
of "call-for-heat" during
the calibration time, or
calibration sequence not
initiated because of lack of
"call-for-heat", or the unit
has been never calibrated
or Calibration is successful
but DIP switch 4 not set to
"normal".
The heater could not start
because the water fl ow was
not established. This can be
caused by an air bubble or a
blockage in the heat engine
water passage, a failed fl ow
sensor or a failed circulation
pump.
An internal diagnostic check
on the board has failed.
TABLE 5
www.hotwater.com
Lockout
type
1.
Check the blower wire harness.
Soft
2.
Change the blower.
3.
Change the board.
1.
Check the water valve wire harness.
Soft
2.
Change the board.
3.
Change the water valve.
Check the proportional gas valve wire
harness, change the board, change
the gas valve assembly
Soft
Check the fl ame rod wire harness,
check line gas pressure. If it is above
5" WC check the fl ame rod and if it
Soft
looks dirty, clean it up using isopropyl
alcohol and a clean cloth, change the
fl ame rod, change the board
1.
Unplug the power cord, check the
DIP switch 4 position and put it in
ON position.
2.
Increase the set point so that a
"call-for-heat" occurs.
Soft
3.
Drain the tank in order to lower the
water temperature so that a "call-
for-heat" is generated.
4.
Set DIP switch 4 to OFF position.
5.
Recalibrate the unit.
6.
Change the board.
1.
Check the water inlet on the heat
engine.
2.
Make a water draw during fi rst 60
seconds after putting the unit in ON
mode (to evacuate possible air from
the heat engine water passage).
3.
Check wire harness for pump, water
Soft
valve and water fl ow sensor.
4.
Check the pump 120Vac voltage
supply (the pump shall be energized
during the heating mode).
5.
Clean or change the water fi lter.
6.
Change board.
7.
Change pump.
8.
Change water valve.
Soft
Change the board.
316888-001 Rev. 00 dRaFt Jun 28 245