Outline Of Judgment; Troubleshooting - Toshiba Carrier RAV-SP180AT2-UL Service Manual

Ac split type outdoor unit super digital inverter
Hide thumbs Also See for Carrier RAV-SP180AT2-UL:
Table of Contents

Advertisement

8-2. Troubleshooting

8-2-1. Outline of judgment

The primary judgment to check whether a trouble occurred in the indoor unit or outdoor unit is carried out with
the following method.
Method to judge the erroneous position by flashing indication on the display part of the indoor unit
(sensors of the receiving part)
The indoor unit monitors the operating status of the air conditioner, and the blocked contents of self-diagnosis
are displayed restricted to the following cases if a protective circuit works.
Lamp indication
Operation Timer
Ready
No indication at all
Operation Timer
Ready
Flash
Operation Timer
Ready
Flash
Operation Timer
Ready
Alternate flash
Operation Timer
Ready
Alternate flash
∗1: These are representative examples and the check code differs according to the outdoor unit to be combined.
Check code
Power supply OFF or miswiring between lamp indication unit and indoor unit
E01
Receiving error
E02
Sending error
E03
Communication stop
E08
Duplicated indoor unit No.
E09
Duplicated master units of remote controller
E10
Communication error between CPUs on indoor unit P.C. board
Wire connection error between indoor units, Indoor power OFF
E18
(Communication stop between indoor header and follower)
Miswiring between indoor unit and outdoor unit or connection erorr
E04
(Communication stop between indoor and outdoor units)
P10
Overflow was detected.
P12
Indoor DC fan error
P03
Outdoor unit discharge temp. error
P04
Outdoor high pressure system error
P05
Negative phase detection error
P07
Heat sink overheat error
P15
Gas leak detection error
P19
4-way valve system error (Indoor or outdoor unit judged.)
P20
Outdoor unit high pressure protection
P22
Outdoor unit: Outdoor unit error
P26
Outdoor unit: Inverter Idc operation
P29
Outdoor unit: Position detection error
Stopped because of error of other indoor unit in a group
P31
(Check codes of E03/L03/L07/L08)
: Go off,
Cause of trouble occurrence
Receiving unit
Protective device of indoor unit worked.
– 47 –
Revised : Feb. 2010
: Go on,
: Flash (0.5 sec.)
Miswiring or wire connection error
between receiving unit and indoor unit
Setup error
Protective device of
outdoor unit worked.
Outdoor unit error
Protective device of
outdoor unit worked.
∗1
∗1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents