Baxi Combi 130 HE Installation And Servicing Instructions page 52

Gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

Gas Valve Fault
230V at A
during ignition ?
YES
230Vdc at B
during ignition ?
NO
Boiler providing heat ?
YES
Replace Main PCB.
52
Supplied By www.heating spares.co Tel. 0161 620 6677
NO
Replace Main PCB.
NO
Lead from Main PCB to
Gas Valve faulty.
NO
Replace Gas Valve.
15.0
Fault Finding
Mains Input
Burner On
&
Fault Neons
Pump
Diverter Valve
A
Gas Valve
Modem PCB
Room Thermostat
Gas Valve Plug
(when unplugged)
B
Transformer
Flow &
Return
Thermistors
Overheat
Thermostats
&
Flow Switches
&
Condensate Trap
Room Control
Display PCB
Fan

Hide quick links: