Standard Flue
B
J
M
H
E
H
16
Supplied By www.heating spares.co Tel. 0161 620 6677
A
K
L
C
N
G
7.0 Site Requirement
7.11
C
Concentric
The maximum equivalent lengths are 4m
(horizontal) or 5m (vertical). There lengths exclude
the standard elbow and flue/terminal assembly
(horizontal) and terminal assembly (vertical).
Twin Flue
The total maximum equivalent flue length is 40m.
NOTE: Each 1m of flue duct should be calculated
as 2m.
D
Any additional "in line" bends in the flue system
must be taken into consideration. Their equivalent
lengths are:
Concentric Pipes: 45º bend
Twin Flue Pipe:
Detailed examples of equivalent flue length
calculation are given in the Installation Guidance
Notes for each flue system type.
(Documents 243501 and 243502 for concentric and
twin pipe respectively).
Key Accessory
Concentric Flue System 110mm diameter
A
B
C
D
Twin Flue System 80mm diameter
E
F
G
Universal Vertical Flue Kits
F
H
J
K
L
M
N
Flue options
93º bend
45º bend (air duct)
45º bend (flue duct)
90º bend (air duct)
90º bend (flue duct)
Size
Straight extension kit
1000mm
500mm
250mm
Bend kit
93°
Bend kit (pair)
45°
Horizontal flue terminal
Clamp
110mm
Straight extension kit
1000mm
500mm
250mm
Bend kit
90°
Bend kit (pair)
45°
Twin flue adaptor kit
Vertical flue terminal
Universal roof tile
25°/50°
Roof cover plate kit
Flat roof flashing
Boiler connection vertical concentric
Clamp
80mm
0.5 m
1.0 m
1.3 m
2.6 m
4.8 m
9.6 m
Baxi Code
Number
241695
241694
241692
241687
241689
243013BAX
243014BAX
238690
238692
238694
246139
246138
242757
242802
243015
243131
243016BAX
242886
238684

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents