Installation & Servicing Instructions Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler These instructions include the Benchmark Commissioning Checklist and should be left with the user for safe keeping.
Page 4
Legislation IMPORTANT - Installation, Commissioning, Service & Repair Baxi declare that no substances harmful to health are contained in the appliance or used during appliance This appliance must be installed in accordance with the manufacturer’s instructions and manufacture. the regulations in force. Read the instructions fully before installing or using the appliance.
Description 1. The Baxi Combi HE Plus Range are fully automatic gas fired wall mounted condensing combination boilers. They are room sealed and fan assisted, and will serve central heating and mains fed domestic hot water.
ONLY. In GB it is necessary to comply with the Water Supply (Water Fittings) Regulations 1999 (or for Scotland, The Water Byelaws 2000, Scotland). The Baxi This boiler is fitted with a flow switch interlock that prevents Combi 133, 100, 80 HE Plus Combination Boilers are an Approved Product under it from firing when the heating demand is satisfied.
Page 19
25mm but the flue deflector kit (part no. 248167) must be fitted. 7. If required a suitable terminal guard is available from Baxi for use with the flue deflector. Top View Rear Flue 8. For fitting under low soffits and eaves it is acceptable for the flue to project upto 500mm from the face of Fig.
Page 23
NOTE: A small amount of water may drain from the boiler in the upright position. Baxi declare that no substances harmful to health Service Guidance Note Label are contained in the appliance or used during on inside of panel construction of the appliance.
Page 26
15. If necessary fit a terminal guard (see Section 7.9). Gasket VERTICAL FLUEING 1. Only a flue approved with the Baxi Combi HE Plus Boiler Range can be used. 2. For information on vertical flues consult the Baxi Flue Guide Brochure or Notes for Guidance supplied with the vertical flue pack.
Screw Hazardous materials are not used in the construction of Baxi products, however reasonable care during service is recommended. When replacing the combustion box door after servicing it is essential that the retaining screws are tightened fully.
Manifold Hazardous materials are not used in the construction of Baxi products, however reasonable care during service is recommended. When replacing the combustion box door after changing components, it is essential that the retaining screws are tightened fully.
Page 64
Conditions of Sale which are available on request. BAX I A Trading Division of Baxi Heating UK, a division of Baxi Group Brooks House, Coventry Road, Warwick. CV34 4LL After Sales Service 08700 60 30 60 Technical Enquiries 08706 049 049 Website www.baxi.co.uk...