Baxi Combi 130 HE Installation And Servicing Instructions page 36

Gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

Three-Way
Diverter Valve
Head
Clip
Wiring Harness
Fits Here
Wiring Harness
Fits Here
Three-Way
Diverter Valve
36
Supplied By www.heating spares.co Tel. 0161 620 6677
Fig. 65
Spigot
Gasket
Fig. 66
13.0 Changing Components
13.10
Three-Way Diverter Valve (Head
Only) (Fig. 65)
If only the head needs replacing:
1. Unplug the wiring harness from the 3-way
diverter valve.
2.Depress the clip and revolve the head through
30° and remove.
3. Fit replacement head and reassemble in
reverse order.
13.11
Three-Way Diverter Valve
(Complete) (Fig. 66)
1. Drain the boiler
(see Section 13.1 paragraph 2 & 3).
2. Unplug the wiring harness from the 3-way
diverter valve.
3. Remove the four socket screws retaining the
3-way valve.
4. Remove the 3-way valve.
5. Fit the new 3-way valve ensuring the gasket
is in place and that the spigots are at the top to
fit into the recesses on the manifold and
reassemble in reverse order.