8.0 Installation
8.7
Making The Electrical Connections
WARNING: This appliance must be earthed.
1. The electrical connection is on the rear left
hand side of the unit.
2. Remove the electrical plug from the hardware
pack.
3. Connect L, N & E into the plug and connect it
to the socket at the back left at the bottom of the
boiler.
4. Remove the metal shield from the hardware
pack and connect it over the plug.
5. If fitting an integral timer please refer to the
instructions supplied with the kit.
8. Remove the electrical box cover and check
the electrical installation for; earth continuity,
short circuits, resistance to earth, correct polarity
and fuse failure (see Section 8.13 Electrical
System Checks).
9. Replace the electrical box cover and secure.
8.8
Connecting an External Timer
1. Undo the two screws securing the small
electrical cover and remove (Fig. 27).
2. To connect an external timer switch circuit,
remove the link wire between terminals 1 & 2
and connect the switch circuit (Figs. 28 & 29 or
29a).
3. A cable clamp is provided for incoming cables.
Mains Input
Isolator
External
Timer
N
L
Filter
N
L
N
L
1
2
Fig. 29a
Optional Live Feed
For An External
Pump
3
4
5